set chassis fpc
Syntax
set chassis fpc fpc-slot { error max-power <power> power (off | on) pfe pfe_id power (off | on) no-vlan-tagging }
Syntax (ACX Series Devices)
set chassis fpc fpc-slot { cfp-to-et error lossless-flow-control pfe pfe_id { power (off | on) core core_id { channel channel_id tunnel-services { bandwidth bandwidth_speed } } } pic sampling-instance power (off | on) max-power <power> pfe pfe_id power (off | on) }
Syntax (PTX10003 Devices)
set chassis fpc fpc-slot { error power (off | on) pfe pfe_id power (off| on) no-vlan-tagging }
Syntax (PTX10004, PTX10008, and PTX10016 Devices)
set chassis fpc fpc-slot { error pic <slot> power (off | on) pfe pfe_id power (off| on) { port <port_no> no-temperature-monitoring } no-vlan-tagging }
Description
(ACX and PTX Series devices) Configure no VLAN tagging for a specific FPC. Additionally, configure power off configuration (PTX10003 devices only).
Options
Available command options vary based on the device model.
auto-speed detection |
Disables automatic speed detection. |
cfp-to-et |
Enable ET interface and remove CFP client. |
lossless-flow-control |
Lossless buffer config for Ethernet Mac pause. |
pfe pfe_id core core_id channel channel_id tunnel-services bandwidth bandwidth_speed |
Select a bandwidth speed for your tunnel interface. Speed options start at 1 gigabit. |
fpc fpc_id |
For PTX devices, fpc_id value is 0 to 15. |
pfe pfe_id power (off | on) |
Individual PFE Power off configuration option is available for ACX7900 and PTX10003 devices only. The reset-pfe error action is available for PFE power off and restart. • Slot range for FPC is 0 to 1 for PTX10003-8T. Slot range for FPC is 0 to 3 for PTX10003-16T. • PFE number range is 0 to 7 for all the FPCs. • If no power configuration is present, then PFE is considered powered ON. |
max-power <power> |
Individual PFE maximum power configuration option is available for ACX7900 devices only. Configure maximum power for the FPC slot. |
no-vlan-tagging |
Individual PFE maximum power configuration option is available for PTX10003 devices only. Configure maximum power for the FPC slot. |
no-temperature-monitoring |
Disable temperature monitoring to explicitly disable optics temperature sensors for EM policy support, on specific WAN ports. |
Usage
Use delete chassis fpc no-vlan-tagging
command to disable
no-vlan-tagging.
Required Privilege Level
maintenance
set chassis fpc (PTX)
user@host> set chassis fpc 1 no-vlan-tagging
Release Information
Command introduced in Junos OS Release 21.3R1.
power-off
option introduced for PTX10003 devices in Junos OS Evolved
Release 22.4R1.
max-power
option introduced for ACX7900 devices in Junos OS Evolved
Release 23.1R1.
tunnel-services
and bandwidth
options introduced for ACX
Series devices in Junos OS Evolved Release 24.2R1.