Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

 
 

show chassis cluster control-interface status

Syntax

Description

Display information about 1G optical fiber HA control port SFP basic, diagnostic data, HA control port line-side and system-side link status information in both standalone and cluster mode.

Required Privilege Level

view

Output Fields

Table 1 lists the output fields for the show chassis cluster control-interface status command.

Table 1: show chassis cluster control-interface status Output Fields

Field Name

Field Parameters

Description

Link Status:

Interface—Specifies the interface number.

 

Line-side—Status for line side.

System-side—Status for system side.

Optical Fiber SFP Status:

Port—Specifies the port number.

Cable type—Specifies the cable type.

Fiber type—Specifies the fiber type model.

Xcvr vendor—Specifies the vendor name.

Xcvr vendor part number—Specifies the vendor part number.

Wave-length—Specifies the wave length number.

Xcvr Firmware—Specifies the firmware version.

JNPR Rev—Specifies the revision number.

MSA Version—Specifies the SFF version number.

Control Ports Optics Diagnostics Information:

Control port 0:

Laser bias current—Specifies the power information.

Laser output power—Specifies the power information.

Module temperature—Specifies the temperature information.

Module voltage—Specifies the voltage information.

Laser receiver power—Specifies the power information.

Alarm/warning flags implemented—Specifies the status of the alarm.

Laser bias current high alarm / low alarm / high warning / low warning—Specifies the status for the laser bias current alarm and warning.

Laser output power high alarm / low alarm / high warning / low warning—Specifies the status for the laser output power alarm and warning.

Module temperature high alarm / low alarm / high warning / low warning—Specifies the status for the module temperature alarm and warning.

Module voltage high alarm / low alarm / high warning / low warning—Specifies the status for the module voltage alarm and warning.

Laser rx power high alarm / low alarm / high warning / low warning—Specifies the status for the laser rx power alarm and warning.

Laser bias current high alarm threshold—Specifies the laser bias current threshold value.

Laser bias current low alarm threshold—Specifies the laser bias current threshold value.

Laser bias current high warning threshold—Specifies the laser bias current threshold value.

Laser bias current low warning threshold—Specifies the laser bias current threshold value.

Laser output power high alarm threshold—Specifies the output power threshold value.

Laser output power low alarm threshold—Specifies the output power threshold value.

Laser output power high warning threshold—Specifies the output power threshold value.

Laser output power low warning threshold—Specifies the output power threshold value.

Module temperature high alarm threshold—Specifies the temperature threshold value.

Module temperature low alarm threshold—Specifies the temperature threshold value.

Module temperature high warning threshold—Specifies the temperature threshold value.

Module temperature low warning threshold—Specifies the temperature threshold value.

Module voltage high alarm threshold—Specifies the voltage threshold value.

Module voltage low alarm threshold—Specifies the voltage threshold value.

Module voltage high warning threshold—Specifies the voltage threshold value.

Module voltage low warning threshold—Specifies the voltage threshold value.

Laser rx power high alarm threshold—Specifies the laser rx power threshold value.

Laser rx power low alarm threshold—Specifies the laser rx power threshold value.

Laser rx power high warning threshold—Specifies the laser rx power threshold value.

Laser rx power low warning threshold—Specifies the laser rx power threshold value.

Control port 1:

Sample Output

show chassis cluster control-interface status

Release Information

Command introduced in Junos OS Release 23.4R1.