show chassis environment ccg
Syntax
show chassis environment ccg <slot>
Description
(PTX5000 Packet Transport Routers only) Display environmental information about the Centralized Clock Generators (CCGs).
Options
none | Display environmental information about all CCGs on the router. |
slot | (Optional) Display environmental information about the specified CCG. Replace slot with 0 or 1. |
Required Privilege Level
view
Output Fields
Table 1 lists the output fields for the show chassis
environment ccg
command. Output fields are listed in the approximate
order in which they appear.
Field Name |
Field Description |
---|---|
|
Status of the CCG: |
|
Temperature of the air flowing past the CCG. |
|
Power required and measured on the CCG. The left column displays the required power, in volts. The right column displays the measured power, in millivolts. |
|
Revision level of the generic bus device. |
Sample Output
show chassis environment ccg (PTX5000)
user@host> show chassis environment ccg CCG 0 status: State Online - Master clock Temperature 31 degrees C / 87 degrees F Power 1.2 V bias 1200 mV 1.8 V 1799 mV 3.3 V 3300 mV 3.3 V bias 3300 mV Bus Revision 103 CCG 1 status: State Offline Power Disabled Temperature 31 degrees C / 87 degrees F Power 1.2 V bias 1198 mV 1.8 V 161 mV 3.3 V 451 mV 3.3 V bias 3311 mV Bus Revision 103
Release Information
Command introduced in Junos OS Release 12.1.