show chassis fpc errors
Syntax
show chassis fpc errors;
Description
Display chassis error information including FPC number, severity of error, number of error occurred, cleared, threshold, and corresponding action.
Error Severity Level |
Default Threshold |
Default Action |
---|---|---|
Fatal |
1 |
Restart the FPC |
Major |
1 |
Get the current state of the FPC and raise an alarm. |
Minor |
10 |
Write a log for the event. |
The MX104 router does not support the show chassis fpc error
CLI
command. This command is not available in MX104 in the Junos OS releases 13.3R7,
15.1R2, 14.1R5, 14.2R4, 13.3R8, and later.
Options
detail | Display the entire list of errors that contribute to a failure for all the FPCs. |
fpc-slot | Display the list of errors pertaining to the FPC installed in a particular slot |
Required Privilege Level
view
Output Fields
Table 1 lists the output
fields for the show chassis fpc errors
command. Output
fields are listed in the approximate order in which they appear.
Field Name |
Field Description |
---|---|
|
The FPC number. |
|
The severity of the error. It can be configured as follows:
|
|
Number of error instances occurred. |
|
Number of error instances cleared. |
|
Configured threshold value. The associated detection and recovery actions are triggered when this threshold value is crossed. |
Action-Taken |
The number of instances of action taken. |
|
The detection and recovery actions that are triggered when the threshold value is crossed.
|
Sample Output
show chassis fpc errors
user@host> show chassis fpc errors FPC Level Occurred Cleared Threshold Action-Taken Action 0 Minor 0 0 10 LOG| Major 0 0 1 GET STATE|ALARM| Fatal 0 0 1 TRAP Pfe-State: pfe-0 -ENABLED | pfe-1 -ENABLED | pfe-2 -ENABLED | pfe-3 -ENABLED | pfe-4 -ENABLED | pfe-5 -ENABLED | pfe-6 -ENABLED | pfe-7 -ENABLED | 1 Minor 0 0 10 LOG| Major 0 0 1 GET STATE|ALARM| Fatal 0 0 1 TRAP Pfe-State: pfe-0 -ENABLED | pfe-1 -ENABLED | pfe-2 -ENABLED | pfe-3 -ENABLED | pfe-4 -ENABLED | pfe-5 -ENABLED | pfe-6 -ENABLED | pfe-7 -ENABLED | 2 Minor 0 0 10 LOG| Major 0 0 1 GET STATE|ALARM| Fatal 0 0 1 TRAP Pfe-State: pfe-0 -ENABLED | pfe-1 -ENABLED | pfe-2 -ENABLED | pfe-3 -ENABLED | pfe-4 -ENABLED | pfe-5 -ENABLED | pfe-6 -ENABLED | pfe-7 -ENABLED | 4 Minor 0 0 10 LOG| Major 0 0 1 GET STATE|ALARM| Fatal 0 0 1 TRAP Pfe-State: pfe-0 -ENABLED | pfe-1 -ENABLED | pfe-2 -ENABLED | pfe-3 -ENABLED | pfe-4 -ENABLED | pfe-5 -ENABLED | pfe-6 -ENABLED | pfe-7 -ENABLED | 5 Minor 0 0 10 LOG| Major 0 0 1 GET STATE|ALARM| Fatal 0 0 1 TRAP Pfe-State: pfe-0 -ENABLED | pfe-1 -ENABLED | pfe-2 -ENABLED | pfe-3 -ENABLED | pfe-4 -ENABLED | pfe-5 -ENABLED | pfe-6 -ENABLED | pfe-7 -ENABLED | 6 Minor 0 0 10 LOG| Major 0 0 1 GET STATE|ALARM| Fatal 0 0 1 TRAP Pfe-State: pfe-0 -ENABLED | pfe-1 -ENABLED | pfe-2 -ENABLED | pfe-3 -ENABLED | pfe-4 -ENABLED | pfe-5 -ENABLED | pfe-6 -ENABLED | pfe-7 -ENABLED | 7 Minor 0 0 10 LOG| Major 0 0 1 GET STATE|ALARM| Fatal 0 0 1 TRAP Pfe-State: pfe-0 -ENABLED | pfe-1 -ENABLED | pfe-2 -ENABLED | pfe-3 -ENABLED | pfe-4 -ENABLED | pfe-5 -ENABLED | pfe-6 -ENABLED | pfe-7 -ENABLED |
show chassis fpc errors (MX Series Routers)
user@host> show chassis fpc errors 0 FPC Scope Category Level Occurred Cleared Threshold Action-Taken Action 0 board functional Minor 1 0 1 2 LOG|CM ALARM| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 GET STATE|RESET memory Minor 0 0 1 0 LOG|CM ALARM| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 GET STATE|RESET io Minor 0 0 1 0 LOG|CM ALARM| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 GET STATE|RESET storage Minor 0 0 1 0 LOG|CM ALARM| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 GET STATE|RESET switch Minor 0 0 1 0 LOG|CM ALARM| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 GET STATE|RESET processing Minor 0 0 1 0 LOG|CM ALARM| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 GET STATE|RESET internal Minor 0 0 1 0 LOG|CM ALARM| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 GET STATE|RESET pfe functional Minor 0 0 1 0 LOG|CM ALARM| Major 0 0 1 0 GET STATE|CM ALARM|DISABLE PFE|RESET PFE Fatal 0 0 1 0 GET STATE|RESET memory Minor 0 0 1 0 LOG|CM ALARM| Major 0 0 1 0 GET STATE|CM ALARM|DISABLE PFE|RESET PFE Fatal 0 0 1 0 GET STATE|RESET io Minor 0 0 1 0 LOG|CM ALARM| Major 0 0 1 0 GET STATE|CM ALARM|DISABLE PFE|RESET PFE Fatal 0 0 1 0 GET STATE|RESET storage Minor 0 0 1 0 LOG|CM ALARM| Major 0 0 1 0 GET STATE|CM ALARM|DISABLE PFE|RESET PFE Fatal 0 0 1 0 GET STATE|RESET switch Minor 0 0 1 0 LOG|CM ALARM| Major 0 0 1 0 GET STATE|CM ALARM|DISABLE PFE|RESET PFE Fatal 0 0 1 0 GET STATE|RESET processing Minor 0 0 1 0 LOG|CM ALARM| Major 0 0 1 0 GET STATE|CM ALARM|DISABLE PFE|RESET PFE Fatal 0 0 1 0 GET STATE|RESET internal Minor 0 0 1 0 LOG|CM ALARM| Major 0 0 1 0 GET STATE|CM ALARM|DISABLE PFE|RESET PFE Fatal 0 0 1 0 GET STATE|RESET Pfe-State: pfe-0 -ENABLED | pfe-1 -ENABLED | pfe-2 -ENABLED | pfe-3 -ENABLED | pfe-4 -ENABLED
Release Information
Command introduced in Junos OS Release 12.3.
Reset PFE output option added in Junos OS Release 21.4R3.