show chassis high-availability information
Syntax
show chassis high-availability information
Description
Display details of the Multinode High Availability status on your security device including health status of the peer node.
Required Privilege Level
view
Output Fields
Table 1 lists
the output fields for the show chassis high-availability information
command. Output fields are listed in the approximate order in which
they appear.
Field Name |
Field Description |
---|---|
|
Node failure codes are:
|
|
|
|
|
HA Hardware Upgrade
Events |
Message on additional SPC3 installation status. |
|
|
|
|
|
|
Sample Output
- show chassis high-availability information
- show chassis high-availability information detail
- show chassis high-availability information (Junos OS 23.4R1)
show chassis high-availability information
user@host> show chassis high-availability information Node failure codes: HW Hardware monitoring LB Loopback monitoring MB Mbuf monitoring SP SPU monitoring CS Cold Sync monitoring SU Software Upgrade Node Status: ONLINE Local-id: 2 Local-IP: 10.22.0.2 HA Peer Information: Peer Id: 1 IP address: 10.22.0.1 Interface: ge-0/0/2.0 Routing Instance: default Encrypted: YES Conn State: DOWN Cold Sync Status: IN PROGRESS Services Redundancy Group: 0 Current State: ONLINE Peer Information: Peer Id: 1 SRG failure event codes: BF BFD monitoring IP IP monitoring IF Interface monitoring CP Control Plane monitoring Services Redundancy Group: 1 Deployment Type: ROUTING Status: ACTIVE Activeness Priority: 1 Preemption: DISABLED Process Packet In Backup State: NO Control Plane State: READY System Integrity Check: N/A Failure Events: NONE Peer Information: Peer Id: 1 Status : BACKUP Health Status: HEALTHY Failover Readiness: READY
show chassis high-availability information detail
user@host> show chassis high-availability information detail Node level Information: Node Status: ONLINE Local-id: 2 Local-IP: 10.22.0.2 HA Peer Information: Peer-ID: 1 IP address: 10.22.0.1 Interface: ge-0/0/2.0 Routing Instance: default Encrypted: YES Conn State: UP Cold Sync Status: COMPLETE Internal Interface: st0.16000 Internal Local-IP: 180.100.1.2 Internal Peer-IP: 180.100.1.1 Internal Routing-instance: __juniper_private1__ Packet Statistics: Receive Error : 0 Send Error : 0 Packet-type Sent Received SRG Status Msg 9 8 SRG Status Ack 8 7 Attribute Msg 3 2 Attribute Ack 2 2 HA Peer Conn events: Dec 11 22:22:18.696 : HA Peer 180.100.1.1 BFD conn came up Dec 11 22:22:25.269 : HA Peer 180.100.1.1 BFD conn went down Dec 11 22:22:31.619 : HA Peer 180.100.1.1 BFD conn came up Cold Synchronization: Status: Cold synchronization completed for: N/A Cold synchronization failed for: N/A Cold synchronization not known for: N/A Current Monitoring Weight: 0 Progress: CS Prereq 1 of 1 SPUs completed 1. if_state sync 1 SPUs completed 2. ha peer conn 1 SPUs completed 3. policy data sync 1 SPUs completed 4. cp ready 1 SPUs completed 5. VPN data sync 1 SPUs completed 6. IPID data sync 1 SPUs completed 7. All SPU ready 1 SPUs completed 8. AppID ready 1 SPUs completed 9. Tunnel Sess ready 1 SPUs completed CS RTO sync 1 of 1 SPUs completed CS Postreq 1 of 1 SPUs completed Statistics: Number of cold synchronization completed: 0 Number of cold synchronization failed: 0 Events: Dec 11 22:22:23.870 : Cold sync for PFE is Post-req check in process Dec 11 22:22:24.872 : Cold sync for PFE is Completed Dec 11 22:22:37.293 : Cold sync for PFE is Post-req check in process Dec 11 22:22:38.291 : Cold sync for PFE is Completed SPU monitoring: Status: Enabled Current monitoring weight: 0 Statistics: SPU up count: 1 NPC up count: 0 SPU down count: 0 NPC down count: 0 Chassis info processing error count: 0 Loopback Information: PIC Name Loopback Nexthop Mbuf ------------------------------------------------- Success Success Success Hardware monitoring: Status: Activation status: Enabled Ctrl Plane Hardware errors: 0 Data Plane Hardware errors: 0 SRGS Information: Services Redundancy Group: 1 Deployment Type: ROUTING Status: BACKUP Activeness Priority: 1 Hold Timer: 1 Services: [ IPSEC ] Process Packet In Backup State: NO Control Plane State: READY System Integrity Check: COMPLETE Peer Information: Failure Events: NONE Peer Id: 1 Last Advertised HA Status: ACTIVE Last Advertised Health Status: HEALTHY Failover Readiness: N/A Signal Route Info: Active Signal Route: IP: 10.39.1.1 Routing Instance: default Status: NOT INSTALLED Backup Signal Route: IP: 10.39.1.2 Routing Instance: default Status: INSTALLED Split-brain Prevention Probe Info: DST-IP: 10.111.0.1 SRC-IP: 10.11.0.1 Routing Instance: default Status: NOT RUNNING Result: N/A Reason: N/A SRG State Change Events: Dec 11 22:21:36.379 : SRG[1] state UNKNOWN -> HOLD, Reason: State machine start Dec 11 22:23:28.889 : SRG[1] state HOLD -> ACTIVE, Reason: Peer state Backup adv received Dec 11 22:23:31.152 : SRG[1] state ACTIVE -> BACKUP, Reason: HA state preemption BFD Monitoring: Status: UNKNOWN SRC-IP: 10.5.0.1 DST-IP: 10.5.0.2 Routing Instance: default Type: SINGLE-HOP IFL Name: ge-0/0/3.0 State: INSTALLED Interface Monitoring: Status: UP IF Name: ge-0/0/4 State: Up IF Name: ge-0/0/3 State: Up
show chassis high-availability information (Junos OS 23.4R1)
user@host> show chassis high-availability information Node failure codes: HW Hardware monitoring LB Loopback monitoring MB Mbuf monitoring SP SPU monitoring CS Cold Sync monitoring SU Software Upgrade Node Status: ONLINE Local-id: 1 Local-IP: 10.22.0.1 Local Forwarding IP: 100.1.1.1 HA Peer Information: Peer Id: 2 IP address: 10.22.0.2 Interface: ge-0/0/2.0 Routing Instance: default Encrypted: YES Conn State: UP Configured BFD Detection Time: 5 * 400ms Cold Sync Status: COMPLETE Peer Forwarding IP: 200.1.1.1 Interface: lo0.0 Peer ICD Conn State: UP Services Redundancy Group: 0 Current State: ONLINE Peer Information: Peer Id: 2 SRG failure event codes: BF BFD monitoring IP IP monitoring IF Interface monitoring CP Control Plane monitoring Services Redundancy Group: 1 Deployment Type: ROUTING Status: ACTIVE Activeness Priority: 200 Preemption: ENABLED Process Packet In Backup State: NO Control Plane State: READY System Integrity Check: N/A Failure Events: NONE Peer Information: Peer Id: 2 Status : BACKUP Health Status: HEALTHY Failover Readiness: READY
Release Information
Command introduced in Junos OS Release 20.4R1.