show chassis pic-mode
Syntax
show chassis pic-mode
<all-members>
<local>
<member member-id>
Description
Display the PIC mode on an EX4500 switch.
The PIC mode must be set to virtual-chassis if the EX4500 switch is cabled into a Virtual Chassis using the dedicated Virtual Chassis ports (VCPs) on the Virtual Chassis module.
This PIC mode setting is not used on an EX4550 switch.
The default PIC mode setting is virtual-chassis.
Use the request chassis pic-mode
command to configure
the PIC mode setting.
Options
none | Display the PIC mode on the member switch where the command is issued. |
all-members | (Optional) Display the PIC mode for all members of the Virtual Chassis configuration. |
local | (Optional) Display the PIC mode on the member switch where the command is issued. |
member member-id | (Optional) Display the PIC mode of the specified member of the Virtual Chassis configuration. |
Required Privilege Level
view
Sample Output
show chassis pic-mode
user@switch> show chassis pic-mode fpc0: -------------------------------------------------------------------------- Pic Mode: Intraconnect
Release Information
Command introduced in Junos OS Release 11.1.