adjacency-loss-hold-time (ANCP)

Syntax

Hierarchy Level

Description

Configure the ANCP agent to monitor, either globally or for a specified neighbor, how long an ANCP adjacency is down and to trigger a state change for the subscriber access line if the hold timer expires before the adjacency comes back up, as indicated by a Port Up message on the access line. By default, there is no delay between detecting an adjacency loss and triggering the state change.

Options

seconds

Duration of period that the ANCP agent monitors loss of adjacency.

  • Default: 0 seconds

  • Range: 0 through 1800 seconds

Required Privilege Level

routing—To view this statement in the configuration.

routing-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 16.1R4.