control-ports
Syntax
control-ports fpc { port; }
Hierarchy Level
[edit chassis cluster]
Description
Enable the specific control port to use as a control link for the chassis cluster. By default, all control ports are disabled.
After connecting the control ports, you need to configure the control ports to setup control links as a step to establish the chassis cluster.
You need to configure a minimum of one control port per chassis of the cluster. If you configure port 0 only, the Juniper Services Redundancy Protocol process (jsrpd) does not send control heartbeats on control link 1 and the counters it sends will show zeroes.
Options
fpc
slot-number
—Flexible PIC Concentrator (FPC) slot number.Note:FPC slot range depends on platform. The maximum range of 0 through 23 applies to SRX5800 devices; for SRX5600 devices, the only applicable range is 0 through 11; for SRX5400 devices, the applicable slot range is 0 through 5. See Chassis Cluster Control Plane Interfaces for details.
port
port-number
—Port number on which to configure the control port.
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 9.2. Support.