examine-fip
Syntax
examine-fip { examine-vn2vn { beacon-period milliseconds; } fc-map fc-map-value; no-fip-snooping-scaling; }
Hierarchy Level
[edit ethernet-switching-options secure-access-port vlan (all | vlan-name)]
Description
This statement supports the original CLI. If your switch runs the Enhanced Layer 2 Software (ELS) CLI, see examine-vn2vf for VN_Port to VF_Port (VN2VF_Port) FIP snooping, and see examine-vn2vn for VN_Port to VN_Port (VN2VN_Port) FIP snooping. For ELS details, see Using the Enhanced Layer 2 Software CLI.
Enable FIP snooping on a specified VLAN. Ensure that the VLAN is a dedicated FCoE VLAN that transports only FCoE traffic.
(QFX Series only) Enable VN2VN_Port FIP snooping on the specified VLAN. The VLAN must be a dedicated FCoE VLAN that transports only VN2VN_Port traffic. One FCoE VLAN cannot support both VN2VF_Port FIP snooping and VN2VN_Port FIP snooping. Configure separate, dedicated FCoE VLANs for VN2VN_Port FIP snooping and VN2VN_Port FIP snooping.
The remaining statements are explained separately. See CLI Explorer.
Required Privilege Level
routing—To view this statement in the configuration.routing-control—To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 10.4.
Statement examine-vn2vn
introduced in Junos OS Release 12.2 for the QFX Series.
Statement no-fip-snooping-scaling
introduced in Junos OS Release 13.2X52-D10
for the QFX Series.