feeds (T640, T1600, and T4000 Routers with Six-Input DC Power Supply)
Syntax
feeds number-of-input-feeds;
Hierarchy Level
[edit chassis pem], [edit chassis lcc lcc-number pem]
Description
Configure the number of input feeds
connected to the six-input DC power supply on T640, T1600, or T4000
routers. The value assigned to the feeds
statement must
be equal to the number of input feeds provided to the power supply.
When providing four or five input feeds on standalone routers,
you must configure the feeds
statement at the [edit
chassis pem]
hierarchy level. When providing four or five input
feeds to an LCC router in a routing matrix, you must configure the feeds
statement at the [edit chassis lcc lcc-number pem]
hierarchy level.
Before configuring input feeds for your router, see the T640 Core Router Hardware Guide, T1600 Core Router Hardware Guide, or T4000 Core Router Hardware Guide for special considerations and for the number of input feeds supported by the router.
All power supplies in the router must use the same number of inputs feeds.
Options
Range: 4 through 6
Default: 6
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 12.1.