no-power-budget

date_range 20-Nov-23

Syntax

content_copy zoom_out_map
no-power-budget;

Hierarchy Level

content_copy zoom_out_map
[edit chassis]

Description

Disable power budgeting. If you disable the power management on the PTX10008, the router keeps all the FRUs powered on by default. The router does not move any of the FRUs to offline state even if it does not have sufficient power. However, in case of a power shortage, a power redundancy alarm is raised as shown in the following example.

content_copy zoom_out_map
user@router> show system alarms

1 alarm currently active

Alarm time Class Description

2019-07-25 21:16:25 UTC Major chassis No Redundant Power