no-zero-suppression

Syntax

Hierarchy Level

Description

Disable zero suppression for gRPC-based sensors. When this feature is enabled, data for a sensor is sent to the collector if the sensor value is zero. You can expect to see all counters, even ones with a value of zero. All key value pair updates will be streamed to a collector without performing any zero suppression. The default behavior without zero suppression is that a device will suppress zero values from streamed data.

To enable zero suppression again (the default), delete the configuration by entering #delete services analytics zero-suppression no-zero-suppression.

Whenever this feature is set or deleted, any existing collector is disconnected.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Change History Table

Feature support is determined by the platform and release you are using. Use Feature Explorer to determine if a feature is supported on your platform.

Release
Description
21.4R1
Statement introduced in Junos OS Release 21.4R1 for MX240, MX280, and MX960 operating with MPC10E-10-MRATE, MPC10E-10C-MRATE, MPC10E-15C-MRATE line cards and MX2010 and MX2020 operating with the MX2K-MPC11E line card.
21.1R1
Statement introduced in Junos Evolved OS Release 21.1R1 for PTX10003-80C and PTX10003-160C and PTX10008​​.
20.4R2