pic-services-logging
Syntax
pic-services-logging { command binary-file-path; disable; failover (alternate-media | other-routing-engine); }
Hierarchy Level
[edit system processes]
Description
Enable PICs to send special logging information to the Routing Engine for archiving on a hard disk.
Options
command binary-file-path
—Path to the binary process.disable
—Disable the PIC services logging process.failover
—Configure the device to reboot if the software process fails four times within 30 seconds, and specify the software to use during the reboot.alternate-media
—Configure the device to switch to backup media that contains a version of the system if a software process fails repeatedly.other-routing-engine
—Instruct the secondary Routing Engine to take primary role if a software process fails. If this statement is configured for a process, and that process fails four times within 30 seconds, the device reboots from the secondary Routing Engine.
Required Privilege Level
system—To view this statement in the configuration.
system-control—To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 8.5.