port (Subscriber Limits)

date_range 20-Nov-23

Syntax

content_copy zoom_out_map
port number {
    limit limit;
}

Hierarchy Level

content_copy zoom_out_map
[edit system services resource-monitor subscribers-limit client-type name fpc slot-number pic number]

Description

Configure the maximum number of subscribers of a client type allowed to be logged in on the specified port. When that number is reached, subsequent logins on the port are denied until the current number of subscribers drops below the maximum allowed. You can also specify the maximum number of subscribers of a client type allowed per MIC, per MPC, and per chassis.

Options

number

Port number.

limit

Maximum number of subscribers.

  • Range: 1 through 256,000

Required Privilege Level

system—To view this statement in the configuration.

system-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 17.3R1.