reassembly-timeout
Syntax
reassembly-timeout seconds;
Hierarchy Level
[edit interfaces interface-name services-options] [edit security flow]
Description
The maximum acceptable time, in seconds, from the receipt of the first and latest fragments in a packet. When the number is exceeded, the packet is dropped.
Options
seconds
—Maximum
seconds allowed.
Range: 1 to 60 seconds.
Default: 4 seconds.
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 12.1.
Statement added in Junos OS Release 20.3R1 for Next Gen Services on MX240, MX480, and MX960 routers.