remote-loop-enable
Syntax
(remote-loop-enable | no-remote-loop-enable);
Hierarchy Level
[edit interfaces interface-name otn-options odu-delay-management]
Description
Enable the remote interface to loop back the delay
measurement pattern to the local interface. Delay is measured by transmitting
a known pattern (delay measurement pattern) in a selected bit of the
delay measurement (DM
) field and measuring the number of
frames that are missed when the delay measurement pattern is received
at the transmitting end (local interface).
Do not enable remote loopback on both ends (local and remote). If you enable remote loopback on both interfaces, the delay measurement pattern is looped back continuously between the two interfaces.
Default
Delay measurement is disabled by default.
Options
remote-loop-enable | Enables loopback of the delay measurement pattern at the remote interface. |
no-remote-loop-enable | Disables loopback of the delay measurement pattern at the remote interface. |
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 17.1.