data-size
Syntax
data-size size;
Junos OS Hierarchy Levels
[edit services rpm bgp], [edit services rpm probe owner test test-name], [edit services rpm twamp client control-connection control-client-name test-session session-name]
Description
Specify the size of the data portion of ICMP probes.
The data-size
statement is not valid with the http-get
or http-metadata-get
probe type.
Options
size
—0 through 65400 for
RPM, for TWAMP the value is from 60 through 1400.
Default: 0 for RPM and 60 for TWAMP.
If you configure the hardware timestamp feature (see Configuring RPM Timestamping on MX, M, T, and PTX Series Routers and EX Series Switches):
The default value of
data-size
is 32 bytes and32
is the minimum value for explicit configuration. The UDP timestamp probe type is an exception; it requires a minimum data size of 52 bytes.The data size must be at least 100 bytes smaller than the default MTU of the interface of the RPM client interface.
Required Privilege Level
system—To view this statement in the configuration.
system-control—To add this statement to the configuration.
Release Information
Statement introduced before Junos OS Release 7.4.
Statement introduced in Junos OS Release 9.3 for EX Series switches.
Statement introduced in Junos OS Release 13.2 for PTX Series Packet Transport routers.
Support at the [edit services rpm twamp client control-connection control-client-name
] hierarchy level introduced
in Junos OS Release 15.1 for MX Series routers.
Statement introduced in Junos OS Evolved Release 20.1R1.