show chassis hardware

Syntax

Syntax (EX Series Devices, MX104, MX204, MX2010, MX2020, MX10003, MX10008, and MX2008 Universal Routing Platforms)

Syntax (TX Matrix Router)

Syntax (TX Matrix Plus Router)

Syntax (MX Series Devices)

Syntax (QFX Series)

Description

Display a list of all Flexible PIC Concentrators (FPCs) and PICs installed in the router or switch chassis, including the hardware version level and serial number.

In the EX Series switch command output, FPC refers to the following:

  • On EX2200 switches, EX3200 switches, EX4200 standalone switches, and EX4500 switches—Refers to the switch; FPC number is always 0.

  • On EX4200 switches in a Virtual Chassis configuration—Refers to the member of a Virtual Chassis; FPC number equals the member ID, from 0 through 9.

  • On EX8208 and EX8216 switches—Refers to a line card; FPC number equals the slot number for the line card.

On QFX3500, QFX5100, and OCX Series standalone switches, and PTX1000 devices both the FPC and FPC number are always 0.

On T4000 Type 5 FPCs, there are no top temperature sensor or bottom temperature sensor parameters. Instead, fan intake temperature sensor and fan exhaust temperature sensors parameters are displayed.

Starting from Junos OS Release 11.4, the output of the show chassis hardware models operational mode command displays the enhanced midplanes FRU model numbers (CHAS-BP3-MX240-S, CHAS-BP3-MX480-S or CHAS-BP3-MX960-S) based on the router. Prior to release 11.4, the FRU model numbers are left blank when the router has enhanced midplanes. Note that the enhanced midplanes are introduced through the Junos OS Release 13.3, but can be supported on all Junos OS releases.

Starting with Junos OS Release 14.1, the output of the show chassis hardware detail | extensive | clei-models | models operational mode command displays the new DC power supply module (PSM) and power distribution unit (PDU) that are added to provide power to the high-density FPC (FPC2-PTX-P1A) and other components in a PTX5000 Packet Transport Router.

Options

none

Display information about hardware. For a TX Matrix router, display information about the TX Matrix router and its attached T640 devices. For a TX Matrix Plus router, display information about the TX Matrix Plus router and its attached devices.

clei-models

(Optional) Display Common Language Equipment Identifier (CLEI) barcode and model number for orderable field-replaceable units (FRUs).

detail

(Optional) Include RAM and disk information in output.

extensive

(Optional) Display ID EEPROM information.

all-members

(MX Series devices only) (Optional) Display hardware-specific information for all the members of the Virtual Chassis configuration.

interconnect-device name

(QFabric systems only) (Optional) Display hardware-specific information for the Interconnect device.

lcc number

(TX Matrix devices and TX Matrix Plus router only) (Optional) On a TX Matrix router, display hardware information for a specified T640 router (line-card chassis) that is connected to the TX Matrix router. On a TX Matrix Plus router, display hardware information for a specified router (line-card chassis) that is connected to the TX Matrix Plus router.

Replace number with the following values depending on the LCC configuration:

  • 0 through 3, when T640 devices are connected to a TX Matrix router in a routing matrix.

  • 0 through 3, when T1600 devices are connected to a TX Matrix Plus router in a routing matrix.

  • 0 through 7, when T1600 devices are connected to a TX Matrix Plus router with 3D SIBs in a routing matrix.

  • 0, 2, 4, or 6, when T4000 devices are connected to a TX Matrix Plus router with 3D SIBs in a routing matrix.

local

(MX Series devices only) (Optional) Display hardware-specific information for the local Virtual Chassis members.

member member-id

(MX Series devices and EX Series switches) (Optional) Display hardware-specific information for the specified member of the Virtual Chassis configuration. Replace member-id variable with a value 0 or 1.

models

(Optional) Display model numbers and part numbers for orderable FRUs and, for components that use ID EEPROM format v2, the CLEI code.

node-device name

(QFabric systems only) (Optional) Display hardware-specific information for the Node device.

satellite [slot-id slot-id | device-alias alias-name]

(Junos Fusion only) (Optional) Display hardware information for the specified satellite device in a Junos Fusion, or for all satellite devices in the Junos Fusion if no satellite devices are specified.

scc

(TX Matrix router only) (Optional) Display hardware information for the TX Matrix router (switch-card chassis).

sfc number

(TX Matrix Plus router only) (Optional) Display hardware information for the TX Matrix Plus router (switch-fabric chassis). Replace number variable with 0.

Additional Information

The show chassis hardware detail command now displays DIMM information for the following Routing Engines, as shown in Table 1.

Table 1: Routing Engines Displaying DIMM Information
Routing Engines Devices

RE-S-1800x2 and RE-S-1800x4

MX240, MX480, and MX960 devices

RE-A-1800x2

M120 and M320 devices

In Junos OS Release 11.4 and later, the output for the show chassis hardware models operational mode command for MX Series devices display the enhanced midplanes FRU model numbers—CHAS-BP3-MX240-S, CHAS-BP3-MX480-S, or CHAS-BP3-MX960-S—based on the router. In releases before Junos OS Release 11.4, the FRU model numbers are left blank when the router has enhanced midplanes. Note that the enhanced midplanes are introduced through Junos OS Release 13.3, but can be supported on all Junos OS releases.

Starting with Junos OS Release 17.3R1, the output of the show chassis hardware command displays the mode in which vMX is running (performance mode or lite mode) in the part number field for the FPC. RIOT-PERF indicates performance mode and RIOT-LITE indicates lite mode.

Starting with Junos OS Release 22.2R1, the RE-S-X6-128G-K Routing Engine (RE) is supported for MX240, MX480, and MX960 devices. View the details of the RE in the command output.

Required Privilege Level

view

Output Fields

Table 2 lists the output fields for the show chassis hardware command. Output fields are listed in the approximate order in which they appear.

Table 2: show chassis hardware Output Fields

Field Name

Field Description

Level of Output

Item

Show information about the device hardware.

All levels

Version

Revision level of the chassis component.

All levels

Part number

Part number of the chassis component.

All levels

Serial number

Serial number of the chassis component. The serial number of the backplane is also the serial number of the router chassis. Use this serial number when you need to contact Juniper Networks Customer Support about the router or switch chassis.

All levels

Assb ID or Assembly ID

(extensive keyword only) Identification number that describes the FRU hardware.

extensive

Assembly Version

(extensive keyword only) Version number of the FRU hardware.

extensive

Assembly Flags

(extensive keyword only) Flags.

extensive

FRU model number

(clei-models, extensive, and models keyword only) Model number of the FRU hardware component.

none specified

CLEI code

(clei-models and extensive keyword only) Common Language Equipment Identifier code. This value is displayed only for hardware components that use ID EEPROM format v2. This value is not displayed for components that use ID EEPROM format v1.

none specified

EEPROM Version

ID EEPROM version used by the hardware component: 0x00 (version 0), 0x01 (version 1), or 0x02 (version 2).

extensive

Description

Brief description of the hardware item:

  • Type of power supply.

  • Type of PIC. If the PIC type is not supported on the current software release, the output states Hardware Not Supported.

  • Type of FPC: FPC Type 1, FPC Type 2, FPC Type 3, FPC Type 4 , or FPC TypeOC192.

    On EX Series switches, a brief description of the FPC.

    The following list shows the PIM abbreviation in the output and the corresponding PIM name.

    • 2x FE—Either two built-in Fast Ethernet interfaces (fixed PIM) or dual-port Fast Ethernet PIM

    • 4x FE—4-port Fast Ethernet ePIM

    • 1x GE Copper—Copper Gigabit Ethernet ePIM (one 10-Mbps, 100-Mbps, or 1000-Mbps port)

    • 1x GE SFP—SFP Gigabit Ethernet ePIM (one fiber port)

    • 2x Serial—Dual-port serial PIM

    • 2x T1—Dual-port T1 PIM

    • 2x E1—Dual-port E1 PIM

    • 2x CT1E1—Dual-port channelized T1/E1 PIM

    • 1x T3—T3 PIM (one port)

    • 1x E3—E3 PIM (one port)

    • 4x BRI S/T—4-port ISDN BRI S/T PIM

    • 4x BRI U—4-port ISDN BRI U PIM

    • 1x ADSL Annex A—ADSL 2/2+ Annex A PIM (one port, for POTS)

    • 1x ADSL Annex B—ADSL 2/2+ Annex B PIM (one port, for ISDN)

    • 2x SHDSL (ATM)—G SHDSL PIM (2-port two-wire module or 1-port four-wire module)

    • 1x TGM550—TGM550 Telephony Gateway Module (Avaya VoIP gateway module with one console port, two analog LINE ports, and two analog TRUNK ports)

    • 1x DS1 TIM510—TIM510 E1/T1 Telephony Interface Module (Avaya VoIP media module with one E1 or T1 trunk termination port and ISDN PRI backup)

    • 4x FXS, 4xFX0, TIM514—TIM514 Analog Telephony Interface Module (Avaya VoIP media module with four analog LINE ports and four analog TRUNK ports)

    • 4x BRI TIM521—TIM521 BRI Telephony Interface Module (Avaya VoIP media module with four ISDN BRI ports)

    • Crypto Accelerator Module—For enhanced performance of cryptographic algorithms used in IP Security (IPsec) services

  • MPC M 16x 10GE—16-port 10-Gigabit Module Port Concentrator that supports SFP+ optical transceivers. (Not on EX Series switches.)

  • For hosts, the Routing Engine type.

  • For small form-factor pluggable transceiver (SFP) modules, the type of fiber: LX, SX, LH, or T.

  • LCD description for EX Series switches (except EX2200 switches).

  • MPC2—1-port MPC2 that supports two separate slots for MICs.

  • MPC3E—1-port MPC3E that supports two separate slots for MICs (MIC-3D-1X100GE-CFP and MIC-3D-20GE-SFP) on MX960, MX480, and MX240 devices. The MPC3E maps one MIC to one PIC (1 MIC, 1 PIC), which differs from the mapping of legacy MPCs.

  • 100GBASE-LR4, pluggable CFP optics

  • Supports the Enhanced MX Switch Control Board with fabric redundancy and existing SCBs without fabric redundancy.

  • Interoperates with existing MX Series line cards, including Flexible Port Concentrators (FPC), Dense Port Concentrators (DPCs), and Modular Port Concentrators (MPCs).

  • MPC4E—Fixed configuration MPC4E that is available in two flavors: MPC4E-3D-32XGE-SFPP and MPC4E-3D-2CGE-8XGE on MX2020, MX960, MX480, and MX240 devices.

  • LCD description for MX Series devices

All levels

Sample Output

show chassis hardware (MX240, MX480, MX960 Devices)

show chassis hardware (MX10008 Router)

show chassis hardware (MX960 Router with MPC10E-10C-MRATE, MPC10E-15C-MRATE line cards)

show chassis hardware (PTX10008 Router)

show chassis hardware (PTX10016 Router Junos OS Evolved Release)

show chassis hardware clei-models (PTX10016 Router)

show chassis hardware models (PTX10003 Router)

show chassis hardware (QFX5700 Router)

show chassis hardware (SRX5800 Router)

show chassis hardware interconnect-device (QFabric Systems)

show chassis hardware models (MX2010 Router)

show chassis hardware node-device (QFabric Systems)

show chassis hardware (ACX Series)

show chassis hardware (MX204)

The show chassis hardware command output does not include information about the fan tray serial number and part number of MX204 routers. This does not affect the fan's functionality.

show chassis hardware (SRX5800)

show chassis hardware (PTX10001-36MR) (400G ZR and 400G ZR-M optics)

show chassis hardware (MX304)

show chassis hardware (ACX7509-FPC-20Y)

show chassis hardware (QFX5230-64CD devices with logical FPC and PIC) (Junos OS Evolved Release)

Release Information

Command introduced before Junos OS Release 7.4.

models option introduced in Junos OS Release 8.2.

sfc option introduced in Junos OS Release 9.6 for the TX Matrix Plus router.

Information for disk and usb introduced in Junos OS Release 15.1X53-D60 for QFX10002, QFX10008, and QFX10016 switches.

pem detail output added in Junos OS Release 21.4R1 for SRX5800.
Note:

Devices and routing platforms use the basic syntax, unless otherwise listed. For example, the EX Series has an additional satellite parameter available.