rising-threshold (Health Monitor)
Syntax
rising-threshold percentage;
Hierarchy Level
[edit snmp health-monitor], [edit snmp health-monitor idp]
Description
Set the upper threshold for the monitored object when you configure a health monitor alarm. By setting a rising and a falling threshold for a monitored object, you can be alerted whenever the value of the variable falls outside the allowable operational range.
Options
percentage
—The
lower threshold for the alarm entry.
Range:
1
through100
Default:
80
percent of the maximum possible value
Required Privilege Level
snmp—To view this statement in the configuration.
snmp-control—To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 8.0.