Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

 
 

Open Issues

Learn about open issues in this release for PTX Series routers.

For the most complete and latest information about known Junos OS Evolved defects, use the Juniper Networks online Junos Problem Report Search application.

General Routing

  • Changing decap only tunnel destination address configuration after tunnel is up might not work and end up using previously configured tunnel destination address for decapsulaton. Once system enters this state any further configuration changes to tunnel configuration are not handled. PR1575724

  • NPU and IFL sensors path not programmed on AFT and Junos OS Evolved based LC.PR1610766

  • Several warning messages show up while the RPD process restarts during performing GRES on a system running Junos OS Evolved. PR1612487

  • Some of the frequencies shall fail performance for PTP-PTP and PTP-1PPS. PR1624478

  • [timing] [ptp] PTX10008 SynE-PTP & SyncE-1pps noise transfer test : Few input test frequencies are expected to fail. PR1624502

  • When per-interface egress and per-sid egress SR sensor statistics are configured using the CLI commands below, the (pushed) MPLS label length does not get included in the output/Tx octets field that gets exported from the sensor.

    PR1646799
  • The OpenSSL project has published security advisories for multiple vulnerabilities resolved in OpenSSL. Please Refer to https://kb.juniper.net/JSA70186 for more information.PR1661450

  • GNOI API SetPackage through remote download is not supported.PR1665185

  • Sometimes BGP and RSVP sessions remain down after quick arpd process disable and enable. Whenever customer encounter such scenario, system can recovered from erroneous state by executing restart routing gracefully in CLI.PR1665362

  • Layer 2 related daemons - lacpd, ifmand, and arpd - when patched using JSU might cause the Junos OS Evolved router to not boot up.PR1676132

  • Junos OS Evolved has a limitation of 255 characters for resource names. Increasing the limit has implications on the CLI output and same changes are needed to be propagated to lower layers where the resources are served from. PR1695980

  • This issue is seen during CLI triggered onlining of the Packet Forwarding Engine, that is, when request chassis fpc slot slot-id pfe pfe-id restart is executed. Please use the workaround provided.PR1699323

  • On Junos OS Evolved Platforms, any UI (user interface) set (configuration, script, license) changes done post software addition are lost after the subsequent reboot.PR1699699

  • SNMP mib jnxOperatingState runningAtFullSpeed does not work on PTX10004 or PTX10008 or PTX10016 Junos OS Evolved platforms.PR1701983

  • On PTX10004 or PTX10008 or PTX10016 Junos OS Evolved platforms, when offlined FPC is removed from chassis, show chassis craft-interface CLI shows Fail for removed FPC. PR1706601

Interfaces and Chassis

  • Sometimes 400G-ZR link does not come up when changed to channelized mode. Workaround (when issue is seen): Perform joji over the interface using below CLI:

    PR1646915

Network Management and Monitoring

  • When maximum-password-length is configured and user tries to configure password whose length exceeds configured maximum-password-length, error is thrown, along with error oktag is also emitted. (Ideally ok tag should not be emitted in an error scenario.) The configuration does not get committed.PR1585855

  • When jnxCos mib is polled at a very high rate and if response from FPCs (evo-aftmand) is delayed (takes around 1 minute) then snmpd-subagent might generate a core file. PR1683517

Routing Policy and Firewall Filters

  • On all Junos OS Evolved platforms, when nested firewall filters are applied as input-list and the sum of length of filter and term names exceed 124, firewalld process might crash and generate alarms. The filter might not get publsihed and might result in traffic being handled incorrectly.PR1651411

  • On all Junos OS Evolved PTX Series platforms, when firewall filter with family inet6 is configured with source-port or destination-port and has next-header and no payload-protocol, error messages are observed causing the filter fail to install.PR1674893

Routing Protocols

  • On all Junos and Junos OS Evolved platforms, when configuring the network instance for openconfig, an error might be observed while executing a commit if the configured network instance type is "default_instance" but the instance name is not default.PR1644421

  • When l2cpd (in the context of xSTP) clears the entries that it has programmed on ppmd, that is, when you delete xSTP configurations from the box, there can be a possibility of ppmd core. If ppmd is in distributed mode then there will be no service impact, else there can be service impact as packet transmission for various protocols will happen via if ppmd is in centralized mode.PR1660299

  • On PTX Series routers enabled with BGP Labeled Unicast family, the rpd process might crash if the IBGP-LU peer is enabled before the EBGP-LU peer, and in the same sequence, the BGP-LU configuration is removed.PR1669514

User Interface and Configuration

  • The system might ask for your password when you are trying to save configuration file.PR1665008

  • Configd-streamer generates core files during commit of wild-carded groups related configuration. The core file is only seen with the wild-carded configuration which is used in the reported fusion test case.PR1674890