Interfaces
-
Support for IS-IS BFD-enabled sub-TLV (MX2010, MX2020, PTX10000, PTX10008, and PTX10016)—Starting in Junos OS Release 22.3R1, the strict BFD feature allows IS-IS to converge only when BFD is up, and it sends the
UPnotification to IS-IS. We've introduced a new state in the IS-IS adjacency state machine (InitStrictBFDstate) to indicate the agreement between routers to support strict BFD. We've also added a new BFD IS-IS Hello (IIH) PDU TLV in IS-IS hello packets.If BFD is unstable, to prevent the traffic from being compromised until the IS-IS adjacency timer expires, configure the hold-down interval (in milliseconds). This configuration delays sending the
UPnotification to the BFD client. After the BFD is up, the hold-down interval starts, and upon expiration, a BFDUPnotification is sent to IS-IS so that IS-IS can start forming an adjacency.We've added the following statements for this feature:
-
strict-bfdat the[edit protocols isis interface name level level ]hierarchy level. -
holddown-intervalat the[edit protocols isis interface interface family inet bfd-liveness-detection]hierarchy level.
[See Configuring BFD, interface (Protocols IS-IS), and bfd-liveness-detection (Protocols IS-IS).]
-