General Routing

  • On ACX1K/2K platforms, when a lo0.x filter is configured under a vrf type routing-instance, any IPv4 transit traffic that makes ARP request to generate to the CE-facing interfaces will fail in ARP resolution due to the ARP request packets are discard by lo0.x filter if no specific term to accept the IPv4 packets. PR1737999

  • Due to software issue with initialization sequence, the PTP encapsulation does not get applied with PTP configuration on ge interfaces. Because of this, PTP feature is impacted on ge interfaces. PR1755852

  • Some Junos OS Releases from 21.4R3 to 22.4R3, might display the Remote fault state as 'Offline' in show interface by default. PR1764243

MPLS