power
Syntax
power (off | on);
Hierarchy Level
[edit chassis fpc slot-number] [edit chassis fpc slot pic], [edit chassis lcc name fpc name pic slot], [edit chassis member name fpc slot pic], [edit chassis fpc slot slc slc-id] [edit chassis feb slot slot-number]
Description
Turn a Flexible PIC Concentrator (FPC), a Physical Interface Card (PIC) in the specified FPC, a sub line card (SLC), or a Forwarding Engine Board (FEB) on or off.
The power (off | on)
command at the edit chassis fpc
slot-number
hierarchy configures the Flexible
PIC Concentrator (FPC) to stay offline or to come online automatically.
The edit chassis fpc slot-number pic
pic-number power off
command
turns off the power to the PIC in the specified FPC.
-
The
power off
command is applicable only to the fixed-configuration MPC with six 40-Gigabit Ethernet ports and twenty-four 10-Gigabit Ethernet ports (MPC5E-40G10G). For other PICs, it is ignored with a syslog message. -
On an EX6200 switch, the power statement has no effect when you configure it for an uplink port FPC on the Switch Fabric and Routing Engine (SRE) module. If you configure the statement for those FPCs, the configuration will be committed, but a message that informs you that the configuration has no effect is logged in the system log. You cannot turn the power on or off for these FPCs.
- The PTX10003-80C and PTX10003-160C routers running Junos OS Evolved do not
support the
set chassis fpc fpc-slot power on
command. Executing this command on an FPC which is offline could cause unintended reboots of the router. -
The
set chassis feb slot slot-number power (off | on)
command is supported on ACX7509 routers.
In Junos Node Slicing, issuing the command set chassis fpc
slot-number power off
on the BSYS (base system)
powers off even those FPCs that are assigned to the Guest Network Functions (GNFs)
in which unified in-service software upgrade (ISSU) is in progress. Learn more about
Junos Node Slicing.
Default
on
Options
off
—Take the FPC (or a PIC in the specified
FPC), or
SLC offline, and configure it to stay offline, as, for example,
after a system reboot.
on
—Bring the FPC (or a PIC in the specified FPC) online, and
configure it to come online automatically, as, for example, after a system
reboot.
slc slc-id
—The ID of the SLC to be powered
off.
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
Release Information
The edit chassis fpc slot-number power (off | on)
statement introduced before Junos OS Release 7.4.
Statement introduced in Junos OS Release 9.4.
The edit chassis fpc slot-number pic
pic-number power off
introduced in Junos OS Release 13.3R2.
The edit chassis fpc slot-number pfe
slot-number power (off | on)
statement
introduced in Junos OS Release 19.1R1.
The edit chassis fpc slot-number slc
slc-id power (off | on)
statement introduced in
Junos OS Release 21.1R1.
The
set chassis feb slot slot-number power (off |
on)
command for ACX7509 routers introduced in Junos OS Evolved Release
21.4R1.