Add an Antivirus Profile
You are here: Security Services > Content Security > Antivirus Profiles.
To add an antivirus profile:
Field |
Function |
---|---|
General | |
Name |
Enter a unique name for the antivirus profile. The maximum length is 29 characters. |
URL Allowlist |
Select the customized object from the list for a given category that are to be bypassed for scanning. |
MIME Allowlist | |
MIME Allowlist |
Select a MIME allowlist from the list. To create a MIME list inline and add it to the MIME allowlist:
|
Exception MIME Allowlist |
Select an exception MIME allowlist from the list. Click Create New MIME list to create and add a MIME pattern list inline. |
Fallback Options | |
Fallback options are used when the antivirus system experiences errors and must fall back to one of the previously configured actions to either deny (block) or permit the object. |
|
Content Size |
Select Block or Log and Permit. If the content size exceeds a set limit, the content is either passed or blocked. The default action is Block. |
Engine Error |
Select Block or Log and Permit to specify whether the scan engine should be blocked (default) or logged and permitted if it is not ready during certain processes. For example, while the signature database is loading. |
Trickling Timeout |
Select Block or Log and Permit to specify whether the time taken to scan should be blocked (default) or logged and permitted if the scan process exceeds the timeout setting in the antivirus profile. |
Out of Resources |
Select Block or Log and Permit to specify whether the resource constraints should be blocked (default) or logged and permitted if the error is received during virus scanning. |
Decompress Layer |
Select Block or Log and Permit to specify whether the number of layers of nested compressed files that the internal antivirus scanner can decompress before the execution of the virus scan. The default action is Block. |
Too many Requests |
Select an option to specify whether the number of messages should be blocked (default) or logged and permitted if the messages received concurrently exceeds the device limits. |
Default Action |
Select a default action to take when an error occurs; Block or Log and Permit. |
Notification Options | |
Use the notification options to configure a method of notifying the user when a fallback occurs or a virus is detected. |
|
Fallback Deny | |
Notify Mail Sender |
Select this option to configure e-mail notifications to notify the administrator about the errors returned by either the scan engine or the scan manager when a fallback action occurs. |
Notification Type |
Select None, Protocol, or Message from the list to specify the type of notification sent when a fallback option of deny is triggered. |
Custom Message Subject |
Enter the subject line text for your custom message for the fallback deny notification. The maximum character length is 255. |
Custom Message |
Enter the customized message text for the fallback deny notification. The maximum character length is 512. |
Fallback Non-Deny | |
Notify Mail Recipient |
Select this option to configure E-mail notifications to notify the recipient when a fallback e-mail option without a deny action is triggered. |
Custom Message Subject |
Enter the subject line for your custom message for the fallback non-deny notification. The maximum character length is 255. |
Custom Message |
Enter the customized message text for the fallback non-deny notification. The maximum character length is 512. |
Virus Detection | |
Notify Mail Sender |
Select this option to configure E-mail notifications to notify the administrator when a virus is detected. |
Notification Type |
Specifies the type of notification to be sent when a virus is detected. Select None, Protocol, or Message from the list to specify the type of notification sent when a virus is detected. |
Custom Message Subject |
Enter the subject line text for your custom message for the virus detection notification. The maximum character length is 255. |
Custom Message |
Enter the customized message text for the virus detection notification. The maximum character length is 512. |