Option: Configuring APS for Layer 2 Circuits
To apply Automatic Protection Switching (APS) to a Layer 2 circuit, you must configure an APS working circuit and a protect circuit on PE router interfaces that support SONET options (such as SONET/SDH, ATM, and ATM2 IQ interfaces) and circuit cross-connect (CCC) encapsulation types. Then, you must configure the working circuit as the primary Layer 2 circuit interface and the protect circuit as the protected Layer 2 circuit interface. Note that APS only protects the PE-CE link and not the entire Layer 2 circuit.
To configure an APS working circuit, include the working-circuit
statement at the [edit interfaces interface-name sonet-options aps]
hierarchy level.
To configure an APS protect circuit, include the protect-circuit
statement at the [edit interfaces interface-name sonet-options aps]
hierarchy level. To configure the primary
Layer 2 circuit interface, include the interface
statement
at the [edit protocols l2circuit neighbor
ip-address]
hierarchy level. To configure the protected
Layer 2 circuit interface, include the protect-interface
statement at the [edit protocols l2circuit neighbor
ip-address interface interface-name]
hierarchy level.
[edit] interfaces { at-0/0/1 { description “ APS protect circuit”; encapsulationCCC-encapsulation-type
; sonet-options { aps { protect-circuitname
; } } } at-1/3/1 { description “APS working circuit”; encapsulationCCC-encapsulation-type
; sonet-options { aps { working-circuitname
; } } } } protocols { l2circuit { neighborip-address
{ interface at-1/3/1.0 { protect-interface at-0/0/1.0; virtual-circuit-idnumber
; } } } }