jnxDomCurrentTable
jnxDomCurrentTable is a table of jnxDomCurrentEntry objects that has DOM information about the router. jnxDomCurrentEntry, whose object ID is {jnxDomCurrentTable 1}, contains the objects listed in Table 1. Objects in the jnxDomCurrentEntry are indexed by ifIndex.
Table 1: jnxDomCurrentEntry
Object | Object ID | Description |
---|---|---|
jnxDomCurrentAlarms | jnxDomCurrentEntry 1 | Identifies all the active DOM alarms on an XFP physical interface on the device. |
jnxDomCurrentAlarmDate | jnxDomCurrentEntry 2 | Indicates the system date and time when the management subsystem learned of the current alarm. |
jnxDomLastAlarms | jnxDomCurrentEntry 3 | Identifies a copy of jnxDomCurrentAlarms before the last set or clear. |
jnxDomCurrentWarnings | jnxDomCurrentEntry 4 | Identifies all the active DOM warnings on an XFP physical interface on this device. |
jnxDomCurrentRxLaserPower | jnxDomCurrentEntry 5 | Indicates the receiver laser power in 0.01 dbm units. |
jnxDomCurrentTxLaserBiasCurrent | jnxDomCurrentEntry 6 | Indicates the receiver laser bias current in 0.001 mA units. |
jnxDomCurrentTxLaserOutputPower | jnxDomCurrentEntry 7 | Indicates the transmitter laser output power in 0.01 dbm units. |
jnxDomCurrentModuleTemperature | jnxDomCurrentEntry 8 | Indicates the module temperature in Celsius (degrees C). |
jnxDomCurrentRxLaserPowerHighAlarmThreshold | jnxDomCurrentEntry 9 | Indicates the receiver laser power high alarm threshold in 0.01 dbm units. |
jnxDomCurrentRxLaserPowerLowAlarmThreshold | jnxDomCurrentEntry 10 | Indicates the receiver laser power low alarm threshold in 0.01 dbm units. |
jnxDomCurrentRxLaserPowerHighWarningThreshold | jnxDomCurrentEntry 11 | Indicates the receiver laser power high warning threshold in 0.01 dbm units. |
jnxDomCurrentRxLaserPowerLowWarningThreshold | jnxDomCurrentEntry 12 | Indicates the receiver laser power low warning threshold in 0.01 dbm units. |
jnxDomCurrentTxLaserBiasCurrentHighAlarmThreshold | jnxDomCurrentEntry 13 | Indicates the transmitter laser bias current high alarm threshold in 0.001 mA units. |
jnxDomCurrentTxLaserBiasCurrentLowAlarmThreshold | jnxDomCurrentEntry 14 | Indicates the transmitter laser bias current low alarm threshold in 0.001 mA units. |
jnxDomCurrentTxLaserBiasCurrentHighWarningThreshold | jnxDomCurrentEntry 15 | Indicates the transmitter laser bias current high warning threshold in 0.001 mA units. |
jnxDomCurrentTxLaserBiasCurrentLowWarningThreshold | jnxDomCurrentEntry 16 | Indicates the transmitter laser bias current low warning threshold in 0.001 mA units. |
jnxDomCurrentTxLaserOutputPowerHighAlarmThreshold | jnxDomCurrentEntry 17 | Indicates the transmitter laser power high alarm threshold in 0.01 dbm units. |
jnxDomCurrentTxLaserOutputPowerLowAlarmThreshold | jnxDomCurrentEntry 18 | Indicates the transmitter laser power low alarm threshold in 0.01 dbm units. |
jnxDomCurrentTxLaserOutputPowerHighWarningThreshold | jnxDomCurrentEntry 19 | Indicates the transmitter laser power high warning threshold in 0.01 dbm units. |
jnxDomCurrentTxLaserOutputPowerLowWarningThreshold | jnxDomCurrentEntry 20 | Indicates the transmitter laser power low warning threshold in 0.01 dbm units. |
jnxDomCurrentModuleTemperatureHighAlarmThreshold | jnxDomCurrentEntry 21 | Indicates the module temperature high alarm threshold in degrees Celsius. |
jnxDomCurrentModuleTemperatureLowAlarmThreshold | jnxDomCurrentEntry 22 | Indicates the module temperature low alarm threshold in degrees Celsius. |
jnxDomCurrentModuleTemperatureHighWarningThreshold | jnxDomCurrentEntry 23 | Indicates the module temperature high warning threshold in degrees Celsius. |
jnxDomCurrentModuleTemperatureLowWarningThreshold | jnxDomCurrentEntry 24 | Indicates the module temperature low warning threshold in degrees Celsius. |