Configuring BERT Testing for CTP Bundles (CTP Menu)
BERTs do not run on bundles that use transparent encoding or on fractional T1/E1 bundles.
To configure BERTs with the CTP Menu:
- From the CTP Main Menu, select 1) Bundle Operations.
- Select 1) CTP.
- Select a bundle from the list.
- Select 8) Runtime Diags.
- Configure the BERT options as described in Table 63.
Field | Function | Your Action |
---|---|---|
BERT Injection | Specifies whether this bundle acts as the BERT transmitter. If the bundle is the BERT transmitter, specifies the direction in which it transmits test data. | Select one:
|
BERT Reception | Specifies whether this bundle acts as the BERT receiver. If the bundle is the BERT receiver, specifies the direction from which it receives test data. The BERT receiver does not disrupt the existing data flow in either direction. | Select one:
|
BERT Pattern | Specifies the type of BERT pattern. BERT patterns are compatible with the external BERT equipment that you are using. All patterns except 2^31-1 are compatible with the Fireberd 6000. When you set up a bidirectional end-to-end BERT, you must configure the same pattern on both bundles. | Select one:
|
BERT Error Inject | The BERT transmitter injects an error into the pattern to verify that an end-to-end BERT has been established. | Enter 5) BERT Error Inject to inject an error into the pattern. |