Configuring BERT Testing for CTP Bundles (CTPView)
BERTs do not run on bundles that use transparent encoding or on fractional T1/E1 bundles.
To configure BERTs with CTPView:
- In the side pane, select Bundle > Diagnostics.
- Click Bit Error Rate Tester.
- Run your mouse over the MouseOver to Select
a Port to Display bar.
A list of bundles configured on the CTP device appears.
- In the table of bundles, select the bundle for which you want to configure BERTs.
- Configure the BERT parameters as described in Table 62.
Table 62: BERT Parameter Settings in CTPView
Field | Function | Your Action |
---|---|---|
BERT Injection | Specifies whether this bundle acts as the BERT transmitter. If the bundle is the BERT transmitter, specifies the direction in which it transmits test data. | Select one:
|
BERT Reception | Specifies whether this bundle acts as the BERT receiver. If the bundle is the BERT receiver, specifies the direction from which it receives test data. The BERT receiver does not disrupt the existing data flow in either direction. | Select one:
|
Patterns | Specifies the type of BERT pattern. BERT patterns are compatible with the external BERT equipment that you are using. All patterns except 2^31-1 are compatible with the Fireberd 6000. When you set up a bidirectional end-to-end BERT, you must configure the same pattern on both bundles. | Select one:
|
Update Rate | Specifies the rate at which CTPView checks the status of the BERT and updates the synchronization status and counters. | Select the number of seconds. |
Inject Error | The BERT transmitter injects an error into the pattern to verify that an end-to-end BERT has been established. | Click the button to inject an error into the pattern. The Error Cnt should increment by one. |