Displaying BERT Status and Counters for CTP Bundles (CTP Menu)

date_range 28-Jan-20

To display BERT status and counters with the CTP Menu:

  1. From the CTP Main Menu, select 1) Bundle Operations.
  2. Select the type of bundle.
  3. Select a bundle from the list.
  4. Select 8) Runtime Diags.
  5. Select 6) BERT counts.
  6. Table 65 describes the BERT status and counters.

Table 65: BERT Status and Counters in the CTP Menu

Field NameDescription

BERT Running time

Number of seconds the test has been running since BERT statistics were cleared.

Sync Seconds

Number of seconds that the local CTP device has been in sync with the remote CTP device.

Errored Seconds

Number of seconds during which there were errors.

Error Count

Number of errors found since BERT statistics were cleared.

Sync Loss Count

Number of times synchronization was lost.

Currently in SYNC

Shows whether the local CTP device is currently in sync with the remote device.

  • YES—The local CTP device is in sync with the remote device.

  • NO—The local CTP device is not in sync with the remote device.