Supported Platforms
show chassis cluster status
Syntax
Release Information
Command modified in Junos OS Release 9.2. Support for dual control ports added in Junos OS Release 10.0. Support for monitoring failures added in Junos OS Release 12.1X46-D20.
Description
Display the failover status of a chassis cluster.
Options
- none—Display the status of all redundancy groups in the chassis cluster.
- redundancy-group group-number—(Optional) Display the status of the specified redundancy group.
Required Privilege Level
view
List of Sample Output
show chassis cluster statusshow chassis cluster status redundancy-group 2
show chassis cluster status
show chassis cluster status
show chassis cluster status
Output Fields
Table 1 lists the output fields for the show chassis cluster status command. Output fields are listed in the approximate order in which they appear.
Table 1: show chassis cluster status Output Fields
Field Name | Field Description |
---|---|
Cluster ID | ID number (1-15) of a cluster is applicable for releases upto 12.1X45-D10. ID number (1-255) is applicable for releases 12.1X45-D10 and later. Setting a cluster ID to 0 is equivalent to disabling a cluster. |
Redundancy-Group | ID number (1-128) of a redundancy group in the chassis cluster. |
Node name | Node (device) in the chassis cluster (node0 or node1). |
Priority | Assigned priority for the redundancy group on that node. |
Status | State of the redundancy group (Primary, Secondary, Lost, or Unavailable).
|
Preempt |
|
Manual failover |
|
Sample Output
show chassis cluster status
user@host> show
chassis cluster status
Cluster ID: 3 Node name Priority Status Preempt Manual failover Redundancy-group: 0, Failover count: 1 node0 254 primary no no node1 2 secondary no no Redundancy-group: 1, Failover count: 1 node0 254 primary no no node1 1 secondary no no
Sample Output
show chassis cluster status redundancy-group 2
user@host> show
chassis cluster status redundancy-group 2
Cluster ID: 14 Node name Priority Status Preempt Manual failover Redundancy-Group: 2, Failover count: 1 node0 50 secondary no no node1 100 primary no no
Sample Output
show chassis cluster status
user@host> show
chassis cluster status
Cluster ID: 15 Node Priority Status Preempt Manual failover Redundancy group: 0 , Failover count: 5 node0 200 primary no no node1 0 lost n/a n/a Redundancy group: 1 , Failover count: 41 node0 101 primary no no node1 0 lost n/a n/a
Sample Output
Sample Output
show chassis cluster status
user@host> show
chassis cluster status
The following output is specific to monitoring failures.
Monitor Failure codes: CS Cold Sync monitoring FL Fabric connection down GR GRES monitoring HW Hardware monitoring IF Interface monitoring IP IP monitoring LB Loopback monitoring MB Mbuf monitoring NH Nexthop monitoring NP NPC monitoring SP SPU monitoring SM Schedule monitoring Cluster ID: 3 Node Priority Status Preempt Manual Monitor-failures Redundancy group: 0 , Failover count: 2 node0 0 secondary no no FL node1 200 primary no no None Redundancy group: 1 , Failover count: 6 node0 0 ineligible no no FL node1 200 primary no no None