show chassis temperature-thresholds
Syntax
Syntax (TX Matrix Router)
Syntax (TX Matrix Plus Router)
Syntax (MX Series Router)
Syntax (QFX Series)
Release Information
Command introduced in Junos OS Release 8.0.
Command introduced in Junos OS Release 9.0 for EX Series switches.
sfc command introduced for the TX Matrix Plus router in Junos OS Release 9.6.
Command introduced in Junos OS Release 11.1 for the QFX Series.
Command introduced in Junos OS Release 12.1 for the T4000 Core Routers.
Command introduced in Junos OS Release 12.1 for PTX Series Packet Transport Switches.
Description
Display chassis temperature threshold settings, in degrees Celsius.
Options
none | — | Display the temperature threshold details. |
all-members | — | (MX Series routers only) (Optional) Display the chassis temperature threshold settings of all member routers in the Virtual Chassis configuration. |
interconnect-device name | — | (QFabric systems only) (Optional) Display the chassis temperature threshold settings of the Interconnect device. |
lcc number | — | (TX Matrix and TX Matrix Plus routers only) (Optional) On a TX Matrix router, display the temperature threshold details of a specified T640 router (or line-card chassis) that is connected to a TX Matrix router. On a TX Matrix Plus router, display the temperature threshold details of a specified T1600 router (or line-card chassis) that is connected to a TX Matrix Plus router. Replace number with a value from 0 through 3. |
local | — | (MX Series routers only) (Optional) Display the chassis temperature threshold settings of the local Virtual Chassis member. |
member member-id | — | (MX Series routers only) (Optional) Display the chassis temperature threshold settings of the specified member of the Virtual Chassis configuration. Replace member-id with a value of 0 or 1. |
node-device name | — | (QFabric systems only) (Optional) Display the chassis temperature threshold settings of the Node device. |
scc | — | (TX Matrix routers only) (Optional) Display the temperature threshold details of the TX Matrix router (or switch-card chassis). |
sfc number | — | (TX Matrix Plus routers only) (Optional) Display the temperature threshold details of the TX Matrix Plus router (or switch-fabric chassis). Replace number with 0. |
Required Privilege Level
view
List of Sample Output
show chassis temperature-thresholdsshow chassis temperature-thresholds (T4000 Core Routers)
show chassis temperature-thresholds (TX Matrix Plus Router)
show chassis temperature-thresholds lcc (TX Matrix Plus Router)
show chassis temperature-thresholds sfc (TX Matrix Plus Router)
show chassis temperature-thresholds (QFX3500 Switch and QFX3600)
show chassis temperature-thresholds interconnect-device (QFabric System)
show chassis temperature-thresholds (PTX5000 Packet Transport Switch)
Output Fields
Table 1 lists the output fields for the show chassis temperature-thresholds command. Output fields are listed in the approximate order in which they appear.
Table 1: show chassis temperature-thresholds Output Fields
Field name | Field Description |
---|---|
Item | Chassis component. If per FRU per slot thresholds are configured, the components about which information is displayed include the chassis, the Routing Engines, FPCs, and FEBs. If per FRU per slot thresholds are not configured, the components about which information is displayed include the chassis and the Routing Engines. |
Fan speed | Note: On the QFX3500 switch and QFX3600 switch, there are three fan speeds: low, medium-low, medium-high, and high. The fan speed changes at the threshold when going from a low speed to a higher speed. When the fan speed changes from a higher speed to a lower speed, the temperature changes two degrees below the threshold. Temperature threshold settings, in degrees Celsius, for the fans to operate at normal and high speeds.
Note: For MX480 Routers, there are three fan speeds: Low, Medium, and High. An alarm is not triggered until the temperature exceeds the threshold settings for a yellow alarm or a red alarm. |
Yellow alarm | Temperature threshold settings, in degrees Celsius, that trigger a yellow alarm.
|
Red alarm | Temperature threshold settings, in degrees Celsius, that trigger a red alarm.
|
Fire Shutdown | (T4000 routers and PTX Series Packet Transport Switches only)—Temperature threshold settings, in degrees Celsius, for the network device to shut down. |
Sample Output
show chassis temperature-thresholds
user@host> show chassis temperature-thresholds
Fan speed Yellow alarm Red alarm (degrees C) (degrees C) (degrees C) Item Normal High Normal Bad fan Normal Bad fan Chassis default 48 54 65 55 75 65 Routing Engine 0 70 80 95 95 110 110 Routing Engine 1 70 80 95 95 110 110 FPC 0 55 60 75 65 90 80 FPC 1 55 60 75 65 90 80 FPC 2 55 60 75 65 90 80 FPC 3 55 60 75 65 90 80 FPC 4 55 60 75 65 90 80 FPC 5 55 60 75 65 90 80 FPC 6 55 60 75 65 90 80 FPC 7 55 60 75 65 90 80 FPC 8 55 60 75 65 90 80 FPC 9 55 60 75 65 90 80 FPC 10 55 60 75 65 90 80 FPC 11 55 60 75 65 90 80
show chassis temperature-thresholds (T4000 Core Routers)
user@host> show chassis temperature-thresholds
Fan speed Yellow alarm Red alarm Fire Shutdown (degrees C) (degrees C) (degrees C) (degrees C) Item Normal High Normal Bad fan Normal Bad fan Normal Chassis default 48 54 65 55 75 65 100 Routing Engine 0 55 65 85 85 100 100 102 Routing Engine 1 55 65 85 85 100 100 102 FPC 0 63 68 75 70 90 83 95 FPC 3 63 68 75 70 90 83 95 FPC 5 56 62 75 63 83 76 95 FPC 6 63 68 75 70 90 83 95 SIB 0 64 70 76 72 87 84 95 SIB 1 64 70 76 72 87 84 95 SIB 2 64 70 76 72 87 84 95 SIB 3 64 70 76 72 87 84 95 SIB 4 64 70 76 72 87 84 95
show chassis temperature-thresholds (TX Matrix Plus Router)
user@host> show chassis temperature-thresholds
sfc0-re0: -------------------------------------------------------------------------- Fan speed Yellow alarm Red alarm (degrees C) (degrees C) (degrees C) Item Normal High Normal Bad fan Normal Bad fan Chassis default 48 54 65 55 75 65 Routing Engine 0 55 65 85 85 100 100 Routing Engine 1 55 65 85 85 100 100 SIB F13 0 64 70 76 72 90 84 SIB F13 3 64 70 76 72 90 84 SIB F13 6 64 70 76 72 90 84 SIB F13 8 64 70 76 72 90 84 SIB F13 11 64 70 76 72 90 84 SIB F13 12 64 70 76 72 90 84 SIB F2S 16 64 70 76 72 90 84 SIB F2S 17 64 70 76 72 90 84 SIB F2S 18 64 70 76 72 90 84 SIB F2S 19 64 70 76 72 90 84 SIB F2S 20 64 70 76 72 90 84 SIB F2S 21 64 70 76 72 90 84 SIB F2S 22 64 70 76 72 90 84 SIB F2S 23 64 70 76 72 90 84 SIB F2S 24 64 70 76 72 90 84 SIB F2S 25 64 70 76 72 90 84 SIB F2S 26 64 70 76 72 90 84 SIB F2S 27 64 70 76 72 90 84 SIB F2S 28 64 70 76 72 90 84 SIB F2S 29 64 70 76 72 90 84 SIB F2S 30 64 70 76 72 90 84 SIB F2S 31 64 70 76 72 90 84 SIB F2S 32 64 70 76 72 90 84 SIB F2S 33 64 70 76 72 90 84 SIB F2S 34 64 70 76 72 90 84 SIB F2S 35 64 70 76 72 90 84 lcc0-re0: -------------------------------------------------------------------------- Fan speed Yellow alarm Red alarm (degrees C) (degrees C) (degrees C) Item Normal High Normal Bad fan Normal Bad fan Chassis default 48 54 65 55 75 65 Routing Engine 0 55 65 85 85 100 100 Routing Engine 1 55 65 85 85 100 100 FPC 1 56 62 75 63 83 76 FPC 3 56 62 75 63 83 76 FPC 4 56 62 75 63 83 76 FPC 6 56 62 75 63 83 76 FPC 7 56 62 75 63 83 76 SIB 0 48 54 65 60 80 75 SIB 1 48 54 65 60 80 75 SIB 2 48 54 65 60 80 75 SIB 3 48 54 65 60 80 75 SIB 4 48 54 65 60 80 75 lcc1-re0: -------------------------------------------------------------------------- Fan speed Yellow alarm Red alarm (degrees C) (degrees C) (degrees C) Item Normal High Normal Bad fan Normal Bad fan Chassis default 48 54 65 55 75 65 Routing Engine 0 55 65 85 85 100 100 Routing Engine 1 55 65 85 85 100 100 FPC 1 56 62 75 63 83 76 FPC 3 56 62 75 63 83 76 FPC 4 56 62 75 63 83 76 FPC 6 56 62 75 63 83 76 ...
show chassis temperature-thresholds lcc (TX Matrix Plus Router)
user@host> show chassis temperature-thresholds lcc 1
lcc1-re0: -------------------------------------------------------------------------- Fan speed Yellow alarm Red alarm (degrees C) (degrees C) (degrees C) Item Normal High Normal Bad fan Normal Bad fan Chassis default 48 54 65 55 75 65 Routing Engine 0 55 65 85 85 100 100 Routing Engine 1 55 65 85 85 100 100 FPC 1 56 62 75 63 83 76 FPC 3 56 62 75 63 83 76 FPC 4 56 62 75 63 83 76 FPC 6 56 62 75 63 83 76 SIB 0 48 54 65 60 80 75 SIB 1 48 54 65 60 80 75 SIB 2 48 54 65 60 80 75 SIB 3 48 54 65 60 80 75 SIB 4 48 54 65 60 80 75
show chassis temperature-thresholds sfc (TX Matrix Plus Router)
user@host> show chassis temperature-thresholds sfc 0
sfc0-re0: -------------------------------------------------------------------------- Fan speed Yellow alarm Red alarm (degrees C) (degrees C) (degrees C) Item Normal High Normal Bad fan Normal Bad fan Chassis default 48 54 65 55 75 65 Routing Engine 0 55 65 85 85 100 100 Routing Engine 1 55 65 85 85 100 100 SIB F13 0 64 70 76 72 90 84 SIB F13 3 64 70 76 72 90 84 SIB F13 6 64 70 76 72 90 84 SIB F13 8 64 70 76 72 90 84 SIB F13 11 64 70 76 72 90 84 SIB F13 12 64 70 76 72 90 84 SIB F2S 16 64 70 76 72 90 84 SIB F2S 17 64 70 76 72 90 84 SIB F2S 18 64 70 76 72 90 84 SIB F2S 19 64 70 76 72 90 84 SIB F2S 20 64 70 76 72 90 84 SIB F2S 21 64 70 76 72 90 84 SIB F2S 22 64 70 76 72 90 84 SIB F2S 23 64 70 76 72 90 84 SIB F2S 24 64 70 76 72 90 84 SIB F2S 25 64 70 76 72 90 84 SIB F2S 26 64 70 76 72 90 84 SIB F2S 27 64 70 76 72 90 84 SIB F2S 28 64 70 76 72 90 84 SIB F2S 29 64 70 76 72 90 84 SIB F2S 30 64 70 76 72 90 84 SIB F2S 31 64 70 76 72 90 84 SIB F2S 32 64 70 76 72 90 84 SIB F2S 33 64 70 76 72 90 84 SIB F2S 34 64 70 76 72 90 84 SIB F2S 35 64 70 76 72 90 84
show chassis temperature-thresholds (QFX3500 Switch and QFX3600)
user@switch> show chassis temperature-thresholds
Fan speed Yellow alarm Red alarm (degrees C) (degrees C) (degrees C) Item Normal High Normal Bad fan Normal Bad fan rmal FPC Sensor TopLeft I 48 56 53 43 56 46 FPC Sensor TopRight I 46 54 51 41 54 44 FPC Sensor TopLeft E 58 65 62 52 65 55 FPC Sensor TopRight E 56 64 61 51 64 54 FPC Sensor TopMiddle I 58 64 61 51 64 54 FPC Sensor TopMiddle E 67 74 71 61 74 64 FPC Sensor Bottom I 59 67 64 54 67 57 FPC Sensor Bottom E 66 73 70 60 73 63 FPC Sensor Die Temp 69 75 72 62 75 65 FPC Sensor Mgmnt Brd I 46 54 51 41 54 44 FPC Sensor Switch I 56 63 60 50 63 53
show chassis temperature-thresholds interconnect-device (QFabric System)
user@switch> show chassis temperature-thresholds interconnect-device
interconnect1
temperature-thresholds interconnect-device interconnect1 Fan speed Yellow alarm Red alarm Item Normal High Normal Bad fan Normal Bad fan Chassis default 48 54 65 55 75 65
show chassis temperature-thresholds (PTX5000 Packet Transport Switch)
user@switch> show chassis temperature-thresholds
user@switch> show chassis temperature-thresholds Fan speed Yellow alarm Red alarm Fire Shutdown (degrees C) (degrees C) (degrees C) (degrees C) Item Normal High Normal Bad fan Normal Bad fan Normal Routing Engine 0 70 75 90 87 102 97 115 Routing Engine 1 70 75 90 87 102 97 115 CB 0 Exhaust A 60 65 78 75 85 80 95 CB 0 Exhaust B 60 65 78 75 85 80 95 CB 1 Exhaust A 60 65 78 75 85 80 95 CB 1 Exhaust B 20 25 65 60 80 75 100 FPC 1 Exhaust A 60 65 78 75 85 80 95 FPC 1 Exhaust B 60 65 78 75 85 80 95 FPC 1 TL0 70 75 90 87 102 97 115 FPC 1 TQ0 70 75 90 87 102 97 115 FPC 1 TL1 70 75 90 87 102 97 115 FPC 1 TQ1 70 75 90 87 102 97 115 FPC 1 TL2 70 75 90 87 102 97 115 FPC 1 TQ2 70 75 90 87 102 97 115 FPC 1 TL3 70 75 90 87 102 97 115 FPC 1 TQ3 70 75 90 87 102 97 115 FPC 2 Exhaust A 60 65 78 75 85 80 95 FPC 2 Exhaust B 60 65 78 75 85 80 95 FPC 2 TL0 70 75 90 87 102 97 115 FPC 2 TQ0 70 75 90 87 102 97 115 FPC 2 TL1 70 75 90 87 102 97 115 FPC 2 TQ1 70 75 90 87 102 97 115 FPC 2 TL2 70 75 90 87 102 97 115 FPC 2 TQ2 70 75 90 87 102 97 115 FPC 2 TL3 70 75 90 87 102 97 115 FPC 2 TQ3 70 75 90 87 102 97 115 PIC 2/0 Ambient 60 65 78 75 85 80 95 PIC 2/0 cfp-2/0/1 60 65 70 67 75 72 85 PIC 2/1 Ambient 60 65 78 75 85 80 95 SIB 0 Exhaust 60 65 78 75 85 80 95 SIB 0 Junction 70 75 90 87 102 97 115 SIB 1 Exhaust 60 65 78 75 85 80 95 SIB 1 Junction 70 75 90 87 102 97 115 SIB 2 Exhaust 60 65 78 75 85 80 95 SIB 2 Junction 70 75 90 87 102 97 115 SIB 3 Exhaust 60 65 78 75 85 80 95 SIB 3 Junction 70 75 90 87 102 97 115 SIB 4 Exhaust 60 65 78 75 85 80 95 SIB 4 Junction 70 75 90 87 102 97 115 SIB 5 Exhaust 60 65 78 75 85 80 95 SIB 5 Junction 70 75 90 87 102 97 115 SIB 6 Exhaust 60 65 78 75 85 80 95 SIB 6 Junction 70 75 90 87 102 97 115 SIB 7 Exhaust 60 65 78 75 85 80 95 SIB 7 Junction 70 75 90 87 102 97 115 SIB 8 Exhaust 60 65 78 75 85 80 95 SIB 8 Junction 70 75 90 87 102 97 115