show chassis environment ccg
Syntax
Release Information
Command introduced in Junos OS Release 12.1.
Description
(PTX Series Packet Transport Switches only) Display environmental information about the Centralized Clock Generators (CCGs).
Options
none | — | Display environmental information about all CCGs on the PTX Packet Transport Switch. |
slot | — | (Optional) Display environmental information about the specified CCG. Replace slot with 0 or 1. |
Required Privilege Level
view
List of Sample Output
show chassis environment ccg (PTX5000)Output Fields
Table 1 lists the output fields for the show chassis environment ccg command. Output fields are listed in the approximate order in which they appear.
Table 1: show chassis environment cb Output Fields
Field Name | Field Description |
---|---|
State | Status of the CCG: Online - Master clock , Online - Standby, or Offline. If two CCGs are installed and online, one is functioning as the master clock, and the other is the standby clock. |
Temperature | Temperature of the air flowing past the CCG. |
Power | Power required and measured on the CCG. The left column displays the required power, in volts. The right column displays the measured power, in millivolts. |
BUS Revision | Revision level of the generic bus device. |
Sample Output
show chassis environment ccg (PTX5000)
user@host> show chassis environment ccg
CCG 0 status: State Online - Master clock Temperature 31 degrees C / 87 degrees F Power 1.2 V bias 1200 mV 1.8 V 1799 mV 3.3 V 3300 mV 3.3 V bias 3300 mV Bus Revision 103 CCG 1 status: State Offline Power Disabled Temperature 31 degrees C / 87 degrees F Power 1.2 V bias 1198 mV 1.8 V 161 mV 3.3 V 451 mV 3.3 V bias 3311 mV Bus Revision 103