show chassis pic
Syntax
Syntax (TX Matrix and TX Matrix Plus Routers)
Syntax (MX Series Routers and EX Series Switches)
Syntax (MX2010 and MX2010 3D Universal Edge Routers)
Syntax (QFX Series)
Syntax (ACX Series Universal Access Routers)
Release Information
Command introduced before Junos OS Release 7.4.
Command introduced in Junos OS Release 9.0 for EX Series switches.
Command introduced in Junos OS Release 11.1 for QFX Series.
Command introduced in Junos OS Release 12.2 for ACX Series Universal Access Routers.
Command introduced in Junos OS Release 12.3 for MX2020 3D Universal Edge Routers.
Command introduced in Junos OS Release 12.3 for MX2010 3D Universal Edge Routers.
Description
Display status information about the PIC installed in the specified Flexible PIC Concentrator (FPC) and PIC slot.
Options
fpc-slot slot-number | — | Display information about the PIC in this particular FPC slot:
|
all-members | — | (MX Series routers and EX Series switches only) (Optional) Display PIC information for all member routers in the Virtual Chassis configuration. |
interconnect-device name | — | (QFabric systems only) (Optional) Display PIC information for a specified Interconnect device. |
lcc number | — | (TX Matrix and TX Matrix Plus routers only) (Optional) On a TX Matrix router, display PIC information for a specified T640 router (or line-card chassis) that is connected to the TX Matrix router. On a TX Matrix Plus router, display PIC information for a specified T1600 router (or line-card chassis) that is connected to the TX Matrix Plus router. Replace number with a value from 0 through 3. |
local | — | (MX Series routers and EX Series switches only) (Optional) Display PIC information for the local Virtual Chassis member. |
member member-id | — | (MX Series routers and EX Series switches only) (Optional) Display PIC information for the specified member of the Virtual Chassis configuration. Replace member-id with a value of 0 or 1. |
node-device name | — | (QFabric systems only) (Optional) Display PIC information for a specified Node device. |
pic-slot slot-number | — | Display information about the PIC in this particular PIC slot. For routers, replace slot-number with a value from 0 through 3. For EX3200 and EX4200 switches, replace slot-number with 0 for built-in network interfaces and 1 for interfaces on uplink modules. For EX8208 and EX8216 switches, replace slot-number with 0. For the QFX3500 standalone switch and the QFabric system, replace slot-number with 0 or 1. |
Required Privilege Level
view
Related Documentation
- ACX, EX, J, M, MX, PTX, T Series
- request chassis pic
- ACX, EX, J, M, MX, PTX, QFX, T Series
- show chassis hardware
- M, MX Series
- Configuring the PIC Type
- T Series
- 100-Gigabit Ethernet PIC Overview
List of Sample Output
show chassis pic fpc-slot pic-slotshow chassis pic fpc-slot pic-slot (PIC Offline)
show chassis pic fpc-slot pic-slot (FPC Offline)
show chassis pic fpc-slot pic-slot (FPC Not Present)
show chassis pic fpc-slot pic-slot (PIC Not Present)
show chassis pic fpc-slot 3 pic-slot 0 (M120 Router)
show chassis pic fpc-slot pic-slot (MX960 Router with Bidirectional Optics)
show chassis pic fpc-slot pic-slot (MX480 Router with 100-Gigabit Ethernet MIC)
show chassis pic fpc-slot pic-slot (MX240, MX480, MX960 Routers with Application Services Modular Line Card)
show chassis pic fpc-slot pic-slot (MX480 Router with MPC4E)
show chassis pic fpc-slot pic-slot (MX2010 Router)
show chassis pic fpc-slot pic-slot (MX2020 Router)
show chassis pic fpc-slot pic-slot (MX2020 Router with MPC4E)
show chassis pic fpc-slot pic-slot (T1600 Router with 100-Gigabit Ethernet PIC)
show chassis pic fpc-slot pic-slot lcc (TX Matrix Router)
show chassis pic fpc-slot pic-slot lcc (TX Matrix Plus Router)
show chassis pic fpc-slot pic-slot (Next-Generation SONET/SDH SFP)
show chassis pic fpc-slot pic-slot (12-Port T1/E1)
show chassis pic fpc-slot 0 pic-slot 1 (4x CHOC3 SONET CE SFP)
show chassis pic fpc-slot 0 pic-slot 0 (SONET/SDH OC3/STM1 [Multi-Rate] MIC with SFP)
show chassis pic fpc-slot 3 pic-slot 0 (8-port Channelized SONET/SDH OC3/STM1 [Multi-Rate] MIC with SFP)
show chassis pic fpc-slot 5 pic-slot 0 (4-port Channelized SONET/SDH OC3/STM1 [Multi-Rate] MIC with SFP)
show chassis pic fpc-slot 1 pic-slot 0 (1-port OC192/STM64 MIC with XFP)
show chassis pic fpc-slot 1 pic-slot 2 (8-port DS3/E3 MIC)
show chassis pic fpc-slot pic-slot (OTN)
show chassis pic fpc-slot pic-slot (QFX3500 Switch)
show chassis pic interconnect-device fpc-slot pic-slot (QFabric Systems)
show chassis pic node-device fpc-slot pic-slot (QFabric System)
show chassis pic fpc-slot 0 pic-slot 1 (ACX2000 Universal Access Router)
show chassis pic FPC-slot 1 PIC-slot 0 (MX Routers with Media Services Blade [MSB])
show chassis pic FPC slot 1, PIC slot 2 (MX Routers with Media Services Blade [MSB])
Output Fields
Table 1 lists the output fields for the show chassis pic command. Output fields are listed in the approximate order in which they appear.
Table 1: show chassis pic Output Fields
Field Name | Field Description |
---|---|
Type | PIC type. Note: On the 1-port OC192/STM64 MICs with the SDH framing mode, the type is displayed as MIC-3D-1STM64-XFP and with the SONET framing mode, the type is displayed as MIC-3D-1OC192-XFP. By default, the 1-port OC192/STM64 MICs displays the type as MIC-3D-1OC192-XFP. |
ASIC type | Type of ASIC on the PIC. |
State | Status of the PIC. State is displayed only when a PIC is in the slot.
|
PIC version | PIC hardware version. |
Uptime | How long the PIC has been online. |
Package | (Multiservices PICs only) Services package supported: Layer-2 or Layer-3. |
Port Number | Port number for the PIC. |
Cable Type | Type of cable connected to the port: LH, LX, or SX. |
PIC Port Information (MX480 Router 100-Gigabit Ethernet CFP) | Port-level information for the PIC.
|
PIC Port Information (MX960 Router Bidirectional Optics ) | Port-level information for the PIC.
|
PIC Port Information (Next-Generation SONET/SDH SFP) | Port-level information for the next-generation SONET/SDH SFP PIC.
|
Multirate Mode | Rate-selectabilty status for the MIC: Enabled or Disabled. |
Channelization | Indicates whether channelization is enabled or disabled on the DS3/E3 MIC. |
Sample Output
show chassis pic fpc-slot pic-slot
user@host> show chassis pic fpc-slot 2 pic-slot
0
PIC fpc slot 2 pic slot 0 information: Type 10x 1GE(LAN), 1000 BASE ASIC type H chip State Online PIC version 1.1 Uptime 1 day, 50 minutes, 58 seconds PIC Port Information: Port Cable Xcvr Xcvr Vendor Number Type Vendor Name Part Number 0 GIGE 1000EX FINISAR CORP. FTRJ8519P1BNL-J3 1 GIGE 1000EX FINISAR CORP. FTRJ-8519-7D-JUN
show chassis pic fpc-slot pic-slot (PIC Offline)
user@host> show chassis pic fpc-slot 1 pic-slot
0
PIC fpc slot 1 pic slot 0 information: State Offline
show chassis pic fpc-slot pic-slot (FPC Offline)
user@host> show chassis pic fpc-slot 1 pic-slot
0
FPC 1 is not online
show chassis pic fpc-slot pic-slot (FPC Not Present)
user@host> show chassis pic fpc-slot 4 pic-slot
0
FPC slot 4 is empty
show chassis pic fpc-slot pic-slot (PIC Not Present)
user@host> show chassis pic fpc-slot 5 pic-slot
2
FPC 5, PIC 2 is empty
show chassis pic fpc-slot 3 pic-slot 0 (M120 Router)
user@host> show chassis pic fpc-slot 3 pic-slot
0
PC slot 3, PIC slot 0 information: Type 2x G/E IQ, 1000 BASE ASIC type IQ GE 2 VLAN-TAG FPGA State Online PIC version 1.16 Uptime 3 hours, 3 minutes PIC Port Information: Port Cable Xcvr Xcvr Vendor Number Type Vendor Name Part Number 0 GIGE 1000SX FINISAR CORP. FTRJ8519P1BNL-J3 1 GIGE 1000SX FINISAR CORP. FTRJ-8519-7D-JUN
show chassis pic fpc-slot pic-slot (MX960 Router with Bidirectional Optics)
user@host> show chassis pic fpc-slot 4 pic-slot
1
FPC slot 4, PIC slot 1 information: Type 10x 1GE(LAN) State Online PIC version 0.0 Uptime 18 days, 5 hours, 41 minutes, 54 seconds PIC port information: Fiber Xcvr vendor Port Cable type type Xcvr vendor part number Wavelength 0 SFP-1000BASE-BX10-D SM SumitomoElectric SBP6H44-J3-BW-49 1490 nm 1 SFP-1000BASE-BX10-D SM SumitomoElectric SBP6H44-J3-BW-49 1490 nm 2 SFP-1000BASE-BX10-D SM SumitomoElectric SBP6H44-J3-BW-49 1490 nm 3 SFP-1000BASE-BX10-D SM OCP TRXBG1LXDBVM2-JW 1490 nm 4 SFP-1000BASE-BX10-D SM OCP TRXBG1LXDBVM2-JW 1490 nm 5 SFP-1000BASE-BX10-U SM SumitomoElectric SBP6H44-J3-BW-31 1310 nm 6 SFP-1000BASE-BX10-U SM SumitomoElectric SBP6H44-J3-BW-31 1310 nm 7 SFP-1000BASE-BX10-U SM OCP TRXBG1LXDBBMH-J1 1310 nm 8 SFP-1000BASE-BX10-U SM OCP TRXBG1LXDBBMH-J1 1310 nm 9 SFP-1000BASE-BX10-U SM SumitomoElectric SBP6H44-J3-BW-31 1310 nm
show chassis pic fpc-slot pic-slot (MX480 Router with 100-Gigabit Ethernet MIC)
user@host> show chassis pic fpc-slot 1 pic-slot
2
FPC slot 1, PIC slot 2 information: Type 1X100GE CFP State Online PIC version 2.10 Uptime 4 minutes, 48 seconds PIC port information: Fiber Xcvr vendor Port Cable type type Xcvr vendor part number Wavelength 0 100GBASE LR4 SM FINISAR CORP. FTLC1181RDNS-J3 1310 nm Xcvr vendor firmware version 1.8
show chassis pic fpc-slot pic-slot (MX240, MX480, MX960 Routers with Application Services Modular Line Card)
user@host>show chassis pic fpc-slot 1 pic-slot 2
FPC slot 1, PIC slot 2 information: Type AS-MXC State Online PIC version 1.0 Uptime 11 hours, 18 minutes, 3 seconds
show chassis pic fpc-slot pic-slot (MX480 Router with MPC4E)
user@host> show chassis pic fpc-slot 3 pic-slot 0
FPC slot 3, PIC slot 0 information: Type 4x10GE SFPP State Online PIC version 0.0 Uptime 41 seconds PIC port information: Fiber Xcvr vendor Wave- Xcvr Port Cable type type Xcvr vendor part number length Firmware 0 10GBASE SR MM OPNEXT, INC. TRS2001EM-0014 850 nm 0.0 1 10GBASE SR MM OPNEXT, INC. TRS2001EM-0014 850 nm 0.0
show chassis pic fpc-slot pic-slot (MX2010 Router)
user@host>show chassis pic fpc-slot 9 pic-slot 3
FPC slot 9, PIC slot 3 information: Type 1X100GE CFP State Online PIC version 0.0 Uptime 14 hours, 51 seconds
show chassis pic fpc-slot pic-slot (MX2020 Router)
user@host>show chassis pic fpc-slot 19 pic-slot 3
FPC slot 19, PIC slot 3 information: Type 4x 10GE(LAN) SFP+ State Online PIC version 0.0 Uptime 1 day, 11 hours, 26 minutes, 36 seconds PIC port information: Fiber Xcvr vendor Wave- Xcvr Port Cable type type Xcvr vendor part number length Firmware 0 10GBASE SR MM SumitomoElectric SPP5200SR-J6-M 850 nm 0.0 1 10GBASE SR MM SumitomoElectric SPP5200SR-J6-M 850 nm 0.0 2 10GBASE SR MM SumitomoElectric SPP5200SR-J6-M 850 nm 0.0 3 10GBASE SR MM SumitomoElectric SPP5200SR-J6-M 850 nm 0.0
show chassis pic fpc-slot pic-slot (MX2020 Router with MPC4E)
user@host> show chassis pic fpc-slot 14 pic-slot 0
FPC slot 14, PIC slot 1 information: Type 1X100GE CFP State Online PIC version 0.0 Uptime 1 day, 2 hours, 19 minutes, 18 seconds PIC port information: Fiber Xcvr vendor Wave- Xcvr Port Cable type type Xcvr vendor part number length Firmware 0 100GBASE SR10 MM Reflex Photonics CF-X12-C11801-50 860 nm 4.7
show chassis pic fpc-slot pic-slot (T1600 Router with 100-Gigabit Ethernet PIC)
user@host> run show chassis pic fpc-slot 3 pic-slot
1
FPC slot 3, PIC slot 1 information: Type 100GE SLOT1 ASIC type Brooklyn 100GE FPGA State Online PIC version 1.3 Uptime 10 minutes, 44 seconds PIC port information: Fiber Xcvr vendor Port Cable type type Xcvr vendor part number Wavelength 0 100GBASE LR4 SM Opnext Inc. TRC5E20ENFSF000F 1310 nm
show chassis pic fpc-slot pic-slot lcc (TX Matrix Router)
user@host> show chassis pic fpc-slot 1 pic-slot
1 lcc 0
lcc0-re0: -------------------------------------------------------------------------- PIC fpc slot 1 pic slot 1 information: Type 4x OC-3 SONET, SMIR ASIC type D chip State Online PIC version 1.2 Uptime 5 days, 2 hours, 12 minutes, 8 seconds
show chassis pic fpc-slot pic-slot lcc (TX Matrix Plus Router)
user@host> show chassis pic pic-slot 0 fpc-slot
8
lcc0-re0: -------------------------------------------------------------------------- FPC slot 8, PIC slot 0 information: Type 1x 10GE(LAN/WAN) State Online Uptime 2 hours, 46 minutes, 23 seconds PIC port information: Fiber Port Cable type type Xcvr vendor part number Wavelength 0 10GBASE ZR SM Opnext Inc. TRF7061BN-LF150 1550 nm 0 10GBASE ZR SM FINISAR CORP. FTRX-1811-3-J2 1550 nm
show chassis pic fpc-slot pic-slot (Next-Generation SONET/SDH SFP)
user@host> show chassis pic fpc-slot 4 pic-slot
0
FPC slot 4, PIC slot 0 information: Type 4x OC-3 1x OC-12 SFP ASIC type D FPGA State Online PIC version 1.3 Uptime 1 day, 50 minutes, 4 seconds PIC port information: Fiber Xcvr vendor Port Cable type type Xcvr vendor part number Wavelength 0 OC48 short reach SM FINISAR CORP. FTRJ1321P1BTL-J2 1310 nm 1 OC3 short reach MM OCP TRPA03MM3BAS-JE 1310 nm 2 OC3 short reach MM OCP TRXA03MM3BAS-JW 1310 nm 3 OC12 inter reach SM FINISAR CORP. FTLF1322P1BTR 1310 nm
show chassis pic fpc-slot pic-slot (12-Port T1/E1)
user@host> show chassis pic fpc-slot 0 pic-slot
3
FPC slot 0, PIC slot 3 information: Type 12x T1/E1 CE State Online PIC version 1.1 CPU load average 1 percent Interrupt load average 0 percent Total DRAM size 128 MB Memory buffer utilization 100 percent Memory heap utilization 4 percent Uptime 1 day, 22 hours, 28 minutes, 12 seconds Internal Clock Synchronization Normal
show chassis pic fpc-slot 0 pic-slot 1 (4x CHOC3 SONET CE SFP)
user@host> show chassis pic fpc-slot 0 pic-slot
1
FPC slot 0, PIC slot 1 information: Type 4x CHOC3 SONET CE SFP State Online PIC version 1.3 CPU load average 1 percent Interrupt load average 0 percent Total DRAM size 128 MB Memory buffer utilization 99 percent Memory heap utilization 4 percent Uptime 1 day, 22 hours, 55 minutes, 37 seconds Internal Clock Synchronization Normal PIC port information: Fiber Xcvr vendor Port Cable type type Xcvr vendor part number Wavelength 0 OC3 short reach MM AVAGO HFBR-57E0P-JU2 n/a 1 OC3 short reach MM AVAGO HFBR-57E0P-JU2 n/a 3 OC3 long reach SM OPNEXT INC TRF5456AVLB314 1310 nm
show chassis pic fpc-slot 0 pic-slot 0 (SONET/SDH OC3/STM1 [Multi-Rate] MIC with SFP)
user@host> show chassis pic fpc-slot 0 pic-slot
0
FPC slot 0, PIC slot 0 information: Type MIC-3D-8OC3OC12-4OC48 State Online PIC version 1.8 Uptime 3 days, 22 hours, 3 minutes, 50 seconds PIC port information: Fiber Xcvr vendor Port Cable type type Xcvr vendor part number Wavelength 1 OC12 inter reach SM FINISAR CORP FTRJ1322P1BTR-J3 1310 nm 7 OC12 inter reach SM FINISAR CORP FTRJ1322P1BTR-J3 1310 nm Multirate Mode Enabled
show chassis pic fpc-slot 3 pic-slot 0 (8-port Channelized SONET/SDH OC3/STM1 [Multi-Rate] MIC with SFP)
user@host> show chassis pic fpc-slot 3 pic-slot
0
FPC slot 3, PIC slot 0 information: Type MIC-3D-8CHOC3-4CHOC12 State Online PIC version 1.9 Uptime 1 hour, 21 minutes, 24 seconds PIC port information: Fiber Xcvr vendor Port Cable type type Xcvr vendor part number Wavelength 0 OC12 short reach SM FINISAR CORP. FTRJ1322P1BTR-J3 1310 nm 1 OC12 short reach SM FINISAR CORP. FTRJ1322P1BTR-J3 1310 nm 2 OC12 inter reach SM FINISAR CORP. FTRJ1322P1BTR-J2 1310 nm 4 OC12 short reach SM FINISAR CORP. FTRJ1322P1BTR-J3 1310 nm 5 OC12 short reach SM FINISAR CORP. FTRJ1322P1BTR-J3 1310 nm 6 OC12 short reach SM FINISAR CORP. FTRJ1322P1BTR-J3 1310 nm 7 OC12 short reach SM FINISAR CORP. FTRJ1322P1BTR-J3 1310 nm
show chassis pic fpc-slot 5 pic-slot 0 (4-port Channelized SONET/SDH OC3/STM1 [Multi-Rate] MIC with SFP)
user@host> show chassis pic fpc-slot 5 pic-slot
0
FPC slot 5, PIC slot 0 information: Type MIC-3D-4CHOC3-2CHOC12 State Online PIC version 1.9 Uptime 1 hour, 21 minutes PIC port information: Fiber Xcvr vendor Port Cable type type Xcvr vendor part number Wavelength 1 OC12 inter reach SM FINISAR CORP. FTRJ1322P1BTR-J3 1310 nm 2 OC12 inter reach SM FINISAR CORP. FTRJ1322P1BTR-J3 1310 nm 3 OC12 short reach SM FINISAR CORP. FTRJ1322P1BTR-J3 1310 nm
show chassis pic fpc-slot 1 pic-slot 0 (1-port OC192/STM64 MIC with XFP)
user@host> show chassis pic fpc-slot 1 pic-slot
0
FPC slot 1, PIC slot 0 information: Type MIC-3D-1OC192-XFP State Online PIC version 1.2 Uptime 1 day, 11 hours, 4 minutes, 6 seconds PIC port information: Fiber Xcvr vendor Port Cable type type Xcvr vendor part number Wavelength 0 OC192 short reach n/a FINISAR CORP. FTLX1412M3BCL-J3 1310 nm
show chassis pic fpc-slot 1 pic-slot 2 (8-port DS3/E3 MIC)
user@host> show chassis pic fpc-slot 1 pic-slot
2
FPC slot 1, PIC slot 2 information: Type MIC-3D-8DS3-E3 State Online PIC version 1.10 Uptime 4 days, 1 hour, 29 minutes, 19 seconds Channelization Mode Disabled
show chassis pic fpc-slot pic-slot (OTN)
user@host> show chassis pic fpc-slot 5 pic-slot
0
PIC fpc slot 5 pic slot 0 information: Type 1x10GE(LAN),OTN ASIC type H chip State Online PIC version 1.0 Uptime 5 minutes, 50 seconds
show chassis pic fpc-slot pic-slot (QFX3500 Switch)
user@switch> show chassis pic fpc-slot 0 pic-slot
0
FPC slot 0, PIC slot 0 information: Type 48x 10G-SFP+ Builtin State Online Uptime 3 days, 3 hours, 5 minutes, 20 seconds
show chassis pic interconnect-device fpc-slot pic-slot (QFabric Systems)
user@switch> show chassis pic interconnect-device
interconnect1 fpc-slot 9 pic-slot 0
FPC slot 9, PIC slot 0 information: Type 16x 40G-GEBuiltin State Online Uptime 2 hours, 47 minutes, 40 seconds
show chassis pic node-device fpc-slot pic-slot (QFabric System)
user@switch> show chassis pic node-device node1
pic-slot 0
FPC slot node1, PIC slot 0 information: Type 48x 10G-SFP+Builtin State Online Uptime 2 hours, 52 minutes, 37 seconds PIC port information: Fiber Xcvr vendor Port Cable type type Xcvr vendor part number Wavelength 0 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 1 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 2 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 3 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 4 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 5 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 6 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 7 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 8 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 9 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 10 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 11 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 12 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 13 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 14 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 15 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 16 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 17 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 18 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 19 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 20 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 21 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 22 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 23 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 24 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 25 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 26 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 27 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 28 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 29 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 30 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 31 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 32 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 33 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 34 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 35 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 36 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 37 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 38 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 39 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 40 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 41 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 42 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 43 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 44 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 45 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 46 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm 47 10GBASE SR MM SumitomoElectric SPP5101SR-J3 850 nm
show chassis pic fpc-slot 0 pic-slot 1 (ACX2000 Universal Access Router)
user@host> show chassis pic fpc-slot 0 pic-slot
1
FPC slot 0, PIC slot 1 information: Type 8x 1GE(LAN) RJ45 Builtin State Online Uptime 6 days, 2 hours, 51 minutes, 11 seconds
show chassis pic FPC-slot 1 PIC-slot 0 (MX Routers with Media Services Blade [MSB])
user@switch> show chassis pic fpc-slot 1 pic-slot
0
FPC slot 1, PIC slot 0 information: Type AS-MSC State Online PIC version 1.6 Uptime 11 hours, 17 minutes, 56 seconds
show chassis pic FPC slot 1, PIC slot 2 (MX Routers with Media Services Blade [MSB])
user@switch> show chassis pic fpc-slot 1 pic-slot
2
Type AS-MXC State Online PIC version 1.0 Uptime 11 hours, 18 minutes, 3 seconds
Published: 2013-04-09
Supported Platforms
Related Documentation
- ACX, EX, J, M, MX, PTX, T Series
- request chassis pic
- ACX, EX, J, M, MX, PTX, QFX, T Series
- show chassis hardware
- M, MX Series
- Configuring the PIC Type
- T Series
- 100-Gigabit Ethernet PIC Overview