    show sflow

    Syntax

    show sflow<collector><interface>

    Release Information

    Command introduced in Junos OS Release 9.3 for EX Series switches.

    Description

    Display default sFlow technology configuration information.

    Options

    none

    Display default sFlow technology configuration information.

    collector

    (Optional) Display standard status information about the specified sFlow collector.

    interface

    (Optional) Display standard status information about the specified sFlow interface.

    Required Privilege Level

    view

    List of Sample Output

    show sflow

    Output Fields

    Table 1 lists the output fields for the show sflow command. Output fields are listed in the approximate order in which they appear.

    Table 1: show sflow Output Fields

    Field Name

    Field Description

    Level of Output

    sFlow

    Status of the feature: enabled or disabled.

    All levels

    Sample rate egress

    Rate at which egress packets are sampled.

    All levels

    Sample rate ingress

    Rate at which ingress packets are sampled.

    All levels

    Sample limit

    Number of packets sampled per second. The sample limit cannot be configured and is set to 300 packets/second.

    All levels

    Polling interval

    Interval at which the sFlow agent polls the interface.

    All levels

    Agent ID

    The IP address assigned to the sFlow agent.

    All levels

    Sample Output

    show sflow

    sFlow       		: Enabled
    Sample rate egress     : 1:1000
    Sample rate ingress		: 1: 2048: Disabled
    Sample limit     : 300 packets/second
    Polling interval	: 20 seconds
    Agent ID				: 10.93.54.7
    Source IP address : 10.93.54.7