connectivity-fault-management (EX Series Switch Only)

Syntax

connectivity-fault-management {action-profile profile-name {action {interface-down;}default-actions {interface-down;}event {adjacency-loss;}}linktrace {age (30m | 10m | 1m | 30s | 10s);path-database-size path-database-size;}maintenance-domain domain-name {level number;mip-half-function (none | default |explicit);name-format (character-string | none | dns | mac+2oct);maintenance-association ma-name {continuity-check {hold-interval minutes;interface-status-tlv;interval (10m | 10s | 1m | 1s| 100ms);loss-threshold number;port-status-tlv;}mep mep-id {auto-discovery;direction down;interface interface-name;remote-mep mep-id {action-profile profile-name;}}}}performance-monitoring {sla-iterator-profiles {profile-name {calculation-weight {delay delay-value;delay-variation delay-variation-value;}cycle-time cycle-time-value;iteration-period iteration-period-value;measurement-type two-way-delay;passive;}}}}

Hierarchy Level

[edit protocols oam ethernet]

Release Information

Statement introduced in Junos OS Release 10.2 for EX Series switches.

performance-monitoring introduced in Junos OS Release 11.4 for EX Series switches.

Description

Configure connectivity fault management for IEEE 802.1ag Operation, Administration, and Management (OAM) support.

The remaining statements are explained separately.

Required Privilege Level

routing—To view this statement in the configuration.

routing-control—To add this statement to the configuration.

Published: 2012-12-07