Navigation
Supported Platforms
interface (OAM CFM, for EX Series Switch Only)
Syntax
interface (interface-name | ((ge- | xe-) (fpc/pic/port | fpc/pic/port.unit-number | fpc/pic/port.unit-number vlan vlan-id)));
Hierarchy Level
[edit protocols oam ethernet connectivity-fault-management maintenance-domain domain-name maintenance-association ma-name mep mep-id]
Release Information
Statement introduced in Junos OS Release 10.2 for EX Series switches.
Description
Configure IEEE 802.1ag Operation, Administration, and Management (OAM) Connectivity Fault Management (CFM) support for the specified interface.
Options
interface-name—Interface to which the MEP is attached. It can be a physical Ethernet interface or a logical interface. If the interface is a trunk interface, the VLAN associated with the interface must have a VLAN ID.
Required Privilege Level
routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.