Configuring the Serial Line Protocol
By default, serial interfaces use the EIA-530 line protocol. You can configure each port on the PIC independently to use one of the following line protocols:
- EIA-530
- V.35
- X.21
To configure the serial line protocol, include the line-protocol statement, specifying the eia530, v.35, or x.21 option:
You can include these statements at the following hierarchy levels:
- [edit interfaces se-pim/0/port serial-options]
- [edit interfaces se-fpc/pic/port serial-options]
For more information about serial interfaces, see the following sections:
Serial Interface Default Settings
EIA-530 Interface Default Settings
If you do not include the line-protocol statement or if you explicitly configure the default EIA-530 line protocol, the default settings are as follows:
![]() | Note: On M Series routers, you can set the DCE clocking mode for EIA-530 interfaces and commit. An error message is not displayed and the CLI is not blocked. |
You can include the line-protocol statement at the following hierarchy levels:
- [edit interfaces se-pim/0/port serial-options]
- [edit interfaces se-fpc/pic/port serial-options]
V.35 Interface Default Settings
If you include the line-protocol v.35 statement, the default settings are as follows:
You can include the line-protocol statement at the following hierarchy levels:
- [edit interfaces se-pim/0/port serial-options]
- [edit interfaces se-fpc/pic/port serial-options]
X.21 Interface Default Settings
If you include the line-protocol x.21 statement, the default settings are as follows:
You can include the line-protocol statement at the following hierarchy levels:
- [edit interfaces se-pim/0/port serial-options]
- [edit interfaces se-fpc/pic/port serial-options]
Invalid Serial Interface Statements
The following sections show the invalid configuration statements for each type of serial interface. If you include the following statements in the configuration, an error message indicates the location of the error and the configuration is not activated.
- Invalid EIA-530 Interface Statements
- Invalid V.35 interface Statements
- Invalid X.21 Interface Statements
Invalid EIA-530 Interface Statements
If you do not include the line-protocol statement or if you explicitly configure the default EIA-530 line protocol, the following statements are invalid:
You can include the line-protocol statement at the following hierarchy levels:
- [edit interfaces se-pim/0/port serial-options]
- [edit interfaces se-fpc/pic/port serial-options]
Invalid V.35 interface Statements
If you include the line-protocol v.35 statement, the following statements are invalid:
You can include the line-protocol statement at the following hierarchy levels:
- [edit interfaces se-pim/0/port serial-options]
- [edit interfaces se-fpc/pic/port serial-options]
Invalid X.21 Interface Statements
If you include the line-protocol x.21 statement, the following statements are invalid:
You can include the line-protocol statement at the following hierarchy levels:
- [edit interfaces se-pim/0/port serial-options]
- [edit interfaces se-fpc/pic/port serial-options]