Supported Platforms
Related Documentation
show chassis lcd
show chassis lcd (EX Series)
show chassis lcd (QFX Series and QFabric Systems)
Release Information
Command introduced in Junos OS Release 9.0 for EX Series switches.
menu option introduced in Junos OS Release 10.2 for EX Series switches.
Command introduced in Junos OS Release 11.1 for the QFX Series.
Command introduced in Junos OS Release 13.1 for QFabric systems.
Description
Display the information that appears on the LCD panel of EX3200, EX3300, EX4200, EX4500, EX6200, and EX8200 switches, XRE200 External Routing Engines, QFX Series standalone switches, and Interconnect devices and Node devices within a QFabric system. Display the status of the currently selected port parameter of the Status LED for each network port on the device.
Options
none | — | Display the information that appears on the LCD panel (for any EX Series member switch in a Virtual Chassis or for XRE200 External Routing Engines, display the information for all Virtual Chassis members). Display the status of the currently selected port parameter of the Status LED for each network port. |
fpc-slot <fpc-slot-number> | — | (Optional) Display the information as follows:
|
interconnect-device device-id | — | (QFabric systems only) (Optional) Display the front panel contents and LED status of all the ports on the Interconnect device. |
menu | — | (Optional) Display the names of the menus and menu options that are currently enabled on the LCD panel. |
menu all-members | — | (EX Series Virtual Chassis member switches or XRE200 External Routing Engines) (Optional) Display the names of the menus and menu options that are currently enabled on the LCD panel for all Virtual Chassis members. |
menu local | — | (EX Series Virtual Chassis member switches or XRE200 External Routing Engines) (Optional) Display the names of the menus and menu options that are currently enabled on the LCD panel for the Virtual Chassis member from which you issued the command. |
menu member member-id | — | (EX Series Virtual Chassis member switches or XRE200 External Routing Engines) (Optional) Display the names of the menus and menu options that are currently enabled on the LCD panel for the specified Virtual Chassis member. |
node-device device-id | — | (QFabric systems only) (Optional) Display the front panel contents and LED status of all the ports on the Node device. |
Required Privilege Level
view
Related Documentation
List of Sample Output
show chassis lcd (Two-Member EX4200 Virtual Chassis)show chassis lcd fpc-slot 1 (EX4200 Virtual Chassis)
show chassis lcd (EX8200 Switch)
show chassis lcd fpc-slot 2 (EX8200 Switch)
show chassis lcd menu (EX4200 Switch)
show chassis lcd menu (EX8200 Switch)
show chassis lcd (QFX3500 Switches)
show chassis lcd (XRE200 External Routing Engine in EX8200 Virtual Chassis)
show chassis lcd interconnect-device (QFabric Systems)
show chassis lcd node-device (QFabric Systems)
Output Fields
Table 1 lists the output fields for the show chassis lcd command. Output fields are listed in the approximate order in which they appear.
Table 1: show chassis lcd Output Fields
Field Name | Field Description |
---|---|
membernumber (XRE200 External Routing Engine) | Member ID of the device whose content is being displayed. |
Front panel contents for slot Front panel contents (EX6200, EX8200 switch, XRE200 External Routing Engine, and QFX Series) | FPC slot number of the switch whose content is being displayed. The number is always 0, except for EX4200 switches in a Virtual Chassis, where it is the member ID value. On EX6200 switches, EX8200 switches, and XRE200 External Routing Engines, no slot number is displayed. On XRE200 External Routing Engines, this field appears under the member number field for each member device in the EX8200 Virtual Chassis. |
LCD screen | The first line displays the hostname (for Virtual Chassis members, displays the member ID, the current role, and hostname; for EX8200 switches, displays RE and the hostname). The second line displays the currently selected port parameter of the Status LED and the alarms counter. The Status LED port parameters are:
|
LEDs status | Current state of the Alarms, System, and Master LEDs (chassis status LEDs). |
Interface | Names of the interfaces on the switch. |
LED (ADM/SPD/DPX/POE) | State of the currently selected port parameter of the Status LED for the interface. The Status LED port parameters are: Note: The XRE200 External Routing Engine always displays the NA parameter. The QFX Series products do not have any of the port parameters listed below.
|
fpcx | On standalone EX Series and QFX Series switches, always 0. On EX Series Virtual Chassis member switches, member ID of the Virtual Chassis member whose LCD menu is displayed. |
Sample Output
show chassis lcd (Two-Member EX4200 Virtual Chassis)
user@switch> show chassis lcd
Front panel contents for slot: 0 --------------------------------- LCD screen: 00:BK switch1 LED:SPD ALARM 00 LEDs status: Alarms LED: Off System LED: Green Master LED: Off Interface LED(ADM/SPD/DPX/POE) ------------------------------------- ge-0/0/0 Off ge-0/0/1 Off ge-0/0/2 Off ge-0/0/3 Off ge-0/0/4 Off ge-0/0/5 Off ge-0/0/6 Off ge-0/0/7 Off ge-0/0/8 Off ge-0/0/9 Off ge-0/0/10 Off ge-0/0/11 Off ge-0/0/12 Off ge-0/0/13 Off ge-0/0/14 Off ge-0/0/15 Off ge-0/0/16 Off ge-0/0/17 Off ge-0/0/18 Off ge-0/0/19 Off ge-0/0/20 Off ge-0/0/21 Off ge-0/0/22 Off ge-0/0/23 Off Front panel contents for slot: 1 --------------------------------- LCD screen: 01:RE switch2 LED:SPD ALARM 01 LEDs status: Alarms LED: Yellow System LED: Green Master LED: Green Interface LED(ADM/SPD/DPX/POE) ------------------------------------- ge-1/0/0 Off ge-1/0/1 Off ge-1/0/2 Off ge-1/0/3 Off ge-1/0/4 Off ge-1/0/5 Off ge-1/0/6 Off ge-1/0/7 Off ge-1/0/8 Off ge-1/0/9 Off ge-1/0/10 Off ge-1/0/11 Off ge-1/0/12 Off ge-1/0/13 Off ge-1/0/14 Off ge-1/0/15 Off ge-1/0/16 Off ge-1/0/17 Off ge-1/0/18 Off ge-1/0/19 Off ge-1/0/20 Off ge-1/0/21 Off ge-1/0/22 Off ge-1/0/23 Off
The output for the show chassis lcd fpc-slot command is the same as the output for the show chassis lcd command.
show chassis lcd fpc-slot 1 (EX4200 Virtual Chassis)
user@switch> show chassis lcd fpc-slot 1
Front panel contents for slot: 1 --------------------------------- LCD screen: 01:RE switch2 LED:SPD ALARM 01 LEDs status: Alarms LED: Yellow System LED: Green Master LED: Green Interface LED(ADM/SPD/DPX/POE) ------------------------------------- ge-1/0/0 Off ge-1/0/1 Off ge-1/0/2 Off ge-1/0/3 Off ge-1/0/4 Off ge-1/0/5 Off ge-1/0/6 Off ge-1/0/7 Off ge-1/0/8 Off ge-1/0/9 Off ge-1/0/10 Off ge-1/0/11 Off ge-1/0/12 Off ge-1/0/13 Off ge-1/0/14 Off ge-1/0/15 Off ge-1/0/16 Off ge-1/0/17 Off ge-1/0/18 Off ge-1/0/19 Off ge-1/0/20 Off ge-1/0/21 Off ge-1/0/22 Off ge-1/0/23 Off
show chassis lcd (EX8200 Switch)
user@switch> show chassis lcd
Front panel contents: --------------------- LCD screen: RE st-8200-r LED:ADM ALARM 01 LEDs status: Alarms LED: Yellow System LED: Yellow Master LED: Green Interface LED(ADM/SPD/DPX) ------------------------------------------ ge-0/0/0 Off ge-0/0/1 Off ge-0/0/2 Off ge-0/0/3 Off ge-0/0/4 Off ge-0/0/5 Off ge-0/0/6 Off ge-0/0/7 Off ge-0/0/8 Off ge-0/0/9 Off ge-0/0/10 Off ge-0/0/11 Off ge-0/0/12 Off ge-0/0/13 Off ge-0/0/14 Off ge-0/0/15 Off ge-0/0/16 Off ge-0/0/17 Off ge-0/0/18 Off ge-0/0/19 Off ge-0/0/20 Off ge-0/0/21 Off ge-0/0/22 Off ge-0/0/23 Off ge-0/0/24 Off ge-0/0/25 Off ge-0/0/26 Off ge-0/0/27 Off ge-0/0/28 Off ge-0/0/29 Off ge-0/0/30 Off ge-0/0/31 Off ge-0/0/32 Off ge-0/0/33 Off ge-0/0/34 Off ge-0/0/35 Off ge-0/0/36 Off ge-0/0/37 Off ge-0/0/38 Off ge-0/0/39 Off ge-0/0/40 Off ge-0/0/41 Off ge-0/0/42 Off ge-0/0/43 Off ge-0/0/44 Off ge-0/0/45 Off ge-0/0/46 Off ge-0/0/47 Off xe-2/0/0 Off xe-2/0/1 Off xe-2/0/2 Off xe-2/0/3 Off xe-2/0/4 Off xe-2/0/5 Off xe-2/0/6 Off xe-2/0/7 Off xe-3/0/0 Off xe-3/0/1 Off xe-3/0/2 Off xe-3/0/3 Off xe-3/0/4 Off xe-3/0/5 Off xe-3/0/6 Off xe-3/0/7 Off xe-5/0/0 Off xe-5/0/1 Off xe-5/0/2 Off xe-5/0/3 Off xe-5/0/4 Off xe-5/0/5 Off xe-5/0/6 On xe-5/0/7 On xe-7/0/5 Off
show chassis lcd fpc-slot 2 (EX8200 Switch)
show chassis lcd fpc-slot 2
Interface LED(ADM/SPD/DPX) ------------------------------------------ xe-2/0/0 Off xe-2/0/1 Off xe-2/0/2 Off xe-2/0/3 Off xe-2/0/4 Off xe-2/0/5 Off xe-2/0/6 Off xe-2/0/7 Off
show chassis lcd menu (EX4200 Switch)
user@switch> show chassis lcd menu
fpc0: -------------------------------------------------------------------------- status-menu status-menu vcp-status status-menu power-status status-menu environ-menu status-menu show-version maintenance-menu maintenance-menu halt-menu maintenance-menu system-reboot maintenance-menu rescue-config maintenance-menu vc-uplink-config maintenance-menu factory-default
On an EX4200 switch in a Virtual Chassis, the output for the show chassis lcd menu all-members command is the same as the output for the show chassis lcd menu command.
show chassis lcd menu (EX8200 Switch)
user@switch> show chassis lcd menu
status-menu status-menu sf-status1-menu status-menu sf-status2-menu status-menu psu-status1-menu status-menu psu-status2-menu status-menu environ-menu status-menu show-version maintenance-menu maintenance-menu halt-menu maintenance-menu system-reboot maintenance-menu rescue-config maintenance-menu factory-default
show chassis lcd (QFX3500 Switches)
user@switch> show chassis lcd
Front panel contents for slot: 0 --------------------------------- LCD screen: 00:RE switch ALARM 01 LEDs status: Status/Beacon LED: Yellow Blinking Interface STATUS LED ACTIVITY LED ------------------------------------------- fte-0/1/0 Off Off
show chassis lcd (XRE200 External Routing Engine in EX8200 Virtual Chassis)
user@external-routing-engine> show chassis lcd
member0: -------------------------------------------------------------------------- Front panel contents: --------------------- LCD screen: RE ex8200-member0 LED:ADM ALARM 04 LEDs status: Alarms LED: Red System LED: Yellow Master LED: Green member1: -------------------------------------------------------------------------- member8: -------------------------------------------------------------------------- Front panel contents: --------------------- LCD screen: BACKUP member9: -------------------------------------------------------------------------- Front panel contents: --------------------- LCD screen: 09:RE xre200-member9 LED: NA ALARM 01 Interface LED(ADM/SPD/DPX/POE) ------------------------------------------ ge-0/0/0 On ge-0/0/1 On ge-0/0/2 On ge-0/0/3 On ge-0/0/4 Off ge-0/0/5 Off ge-0/0/6 Off ge-0/0/7 Off ge-0/0/8 Off ge-0/0/9 Off ge-0/0/10 On ge-0/0/11 Off ge-0/0/12 Off ge-0/0/13 Off ge-0/0/14 Off ge-0/0/15 Off ge-0/0/16 Off ge-0/0/17 Off ge-0/0/18 Off ge-0/0/19 Off ge-0/0/20 Off ge-0/0/21 Off ge-0/0/22 Off ge-0/0/23 Off ge-0/0/24 Off ge-0/0/25 Off ge-0/0/26 Off ge-0/0/27 Off ge-0/0/28 Off ge-0/0/29 Off ge-0/0/30 Off ge-0/0/31 Off ge-0/0/32 Off ge-0/0/33 Off ge-0/0/34 Off ge-0/0/35 Off ge-0/0/36 Off ge-0/0/37 Off ge-0/0/38 Off ge-0/0/39 Off ge-0/0/40 On ge-0/0/41 On ge-0/0/42 On ge-0/0/43 On ge-0/0/44 On ge-0/0/45 On ge-0/0/46 On ge-0/0/47 On ge-16/0/0 On ge-16/0/1 Off ge-16/0/2 On ge-16/0/3 Off ge-16/0/4 On ge-16/0/5 Off ge-16/0/6 On ge-16/0/7 Off ge-16/0/8 Off ge-16/0/9 Off ge-16/0/10 Off ge-16/0/11 Off ge-16/0/12 Off ge-16/0/13 On ge-16/0/14 Off ge-16/0/15 On ge-16/0/16 Off ge-16/0/17 On ge-16/0/18 On ge-16/0/19 On ge-16/0/20 On ge-16/0/21 Off ge-16/0/22 On ge-16/0/23 Off ge-16/0/24 Off ge-16/0/25 Off ge-16/0/26 On ge-16/0/27 Off ge-16/0/28 Off ge-16/0/29 Off ge-16/0/30 On ge-16/0/31 Off ge-16/0/32 On ge-16/0/33 On ge-16/0/34 On ge-16/0/35 Off ge-16/0/36 On ge-16/0/37 Off ge-16/0/38 Off ge-16/0/39 Off ge-16/0/40 Off ge-16/0/41 Off ge-16/0/42 On ge-16/0/43 Off ge-16/0/44 Off ge-16/0/45 Off ge-16/0/46 Off ge-16/0/47 Off xe-19/0/0 Off xe-19/0/1 On xe-19/0/2 On xe-19/0/3 On xe-19/0/4 On xe-19/0/5 On ge-22/0/0 Off ge-22/0/1 Off ge-22/0/2 On ge-22/0/3 Off ge-22/0/4 On ge-22/0/5 On ge-22/0/6 On ge-22/0/7 On ge-22/0/8 Off ge-22/0/9 Off ge-22/0/10 Off ge-22/0/11 Off ge-22/0/12 Off ge-22/0/13 Off ge-22/0/14 Off ge-22/0/15 Off ge-22/0/16 On ge-22/0/17 Off ge-22/0/18 On ge-22/0/19 Off ge-22/0/20 On ge-22/0/21 Off ge-22/0/22 On ge-22/0/23 Off ge-22/0/24 On ge-22/0/25 Off ge-22/0/26 Off ge-22/0/27 Off ge-22/0/28 Off ge-22/0/29 Off ge-22/0/30 Off ge-22/0/31 Off ge-22/0/32 On ge-22/0/33 Off ge-22/0/34 On ge-22/0/35 Off ge-22/0/36 Off ge-22/0/37 Off ge-22/0/38 Off ge-22/0/39 Off ge-22/0/40 Off ge-22/0/41 Off ge-22/0/42 Off ge-22/0/43 Off ge-22/0/44 Off ge-22/0/45 Off ge-22/0/46 Off ge-22/0/47 Off
show chassis lcd interconnect-device (QFabric Systems)
show chassis lcd interconnect-device IC-F1012
Front Panel Module Information --------------------------------- LCD screen: IC-F1012 3 Alarms active LEDs status: Status LED: Green Power LED : Green Major Alarm LED: off Minor Alarm LED: Yellow Fan 0 LED : Green Fan 1 LED : Green Fan 2 LED : Green Fan 3 LED : Green Fan 4 LED : Green Fan 5 LED : Green Fan 6 LED : Green Fan 7 LED : Green Fan 8 LED : Green Fan 9 LED : Green PEM 0 LED : Green PEM 1 LED : Green PEM 2 LED : Green PEM 3 LED : off PEM 4 LED : off PEM 5 LED : off LED info for: CB - 0 --------------------------------- LEDs status: Status LED: Green Mastership LED: Green Interface STATUS LED LINK/ACTIVITY LED --------------------------------------------------------- IC-F1012:pme0 : Green N/A IC-F1012:pme1 : Green N/A IC-F1012:pme2 : off N/A IC-F1012:pme3 : off N/A LED info for: CB - 1 --------------------------------- LEDs status: Status LED: Green Mastership LED: Amber Interface STATUS LED LINK/ACTIVITY LED --------------------------------------------------------- IC-F1012:pme0 : Green N/A IC-F1012:pme1 : Green N/A IC-F1012:pme2 : off N/A IC-F1012:pme3 : off N/A LED info for: FC 0 FPC - 0 --------------------------------- LEDs status: Status LED: Green Interface STATUS LED LINK/ACTIVITY LED --------------------------------------------------------- IC-F1012:fte-0/0/0 Green N/A IC-F1012:fte-0/0/1 Green N/A IC-F1012:fte-0/0/2 Green N/A IC-F1012:fte-0/0/3 Green N/A IC-F1012:fte-0/0/4 Green N/A LED info for: FC 1 FPC - 1 --------------------------------- LEDs status: Status LED: Green Interface STATUS LED LINK/ACTIVITY LED --------------------------------------------------------- IC-F1012:fte-1/0/0 Green N/A IC-F1012:fte-1/0/1 Green N/A IC-F1012:fte-1/0/2 Green N/A IC-F1012:fte-1/0/3 Green N/A IC-F1012:fte-1/0/4 Green N/A LED info for: RC 0 FPC - 8 --------------------------------- LEDs status: Status LED: Green LED info for: RC 1 FPC - 9 --------------------------------- LEDs status: Status LED: Green LED info for: RC 2 FPC - 10 --------------------------------- LEDs status: Status LED: Green LED info for: RC 3 FPC - 11 --------------------------------- LEDs status: Status LED: Green LED info for: RC 4 FPC - 12 --------------------------------- LEDs status: Status LED: Green LED info for: RC 5 FPC - 13 --------------------------------- LEDs status: Status LED: Green LED info for: RC 6 FPC - 14 --------------------------------- LEDs status: Status LED: Green LED info for: RC 7 FPC - 15 --------------------------------- LEDs status: Status LED: Green
show chassis lcd node-device (QFabric Systems)
show chassis lcd node-device P3774-C
Front panel contents for: P3774-C ----------------------------------- LCD screen: P3774-C LEDs status: Status/Beacon LED: Yellow Blinking Interface STATUS LED LINK/ACTIVITY LED --------------------------------------------------------- P3774-C:xe-0/0/6 Green Green P3774-C:xe-0/0/7 Green Green P3774-C:ge-0/0/10 Green Green P3774-C:ge-0/0/11 Green Green Blinking P3774-C:ge-0/0/12 Green Off P3774-C:ge-0/0/13 Green Green Blinking P3774-C:ge-0/0/20 Green Green P3774-C:ge-0/0/21 Green Green P3774-C:ge-0/0/22 Green Green Blinking P3774-C:ge-0/0/23 Green Off P3774-C:ge-0/0/30 Green Green P3774-C:ge-0/0/31 Green Green P3774-C:ge-0/0/32 Green Green Blinking P3774-C:ge-0/0/33 Green Green Blinking P3774-C:fte-0/1/0 Green Green P3774-C:fte-0/1/1 Green Green Blinking P3774-C:fte-0/1/2 Green Green Blinking P3774-C:fte-0/1/3 Green Green