Description
(QFabric systems only) Display the status of the two cooling system zones on the Interconnect device. Zone 1 consists of eight (0 – 7) front cards, which are cooled by two fan trays. Zone 2 consists of two control boards and eight rear cards, which are cooled by eight (0 – 7) fan trays. On MX2010 and MX2020 routers, display the status of the cooling system zones of the chassis. Zone 0 consists of the Control Board, ten (0–9) FPCs, and their respective PICs, Switch Fabric Boards, and Adapter Cards. Zone 1 consists of the Routing Engine, Control Board, and Switch Processor Mezzanine Boards.
Options
detail | — | (MX2010 and MX2020 routers only) (Optional) Display detailed status of the cooling system zones. |
detail device-name | — | (QFabric systems only) (Optional) Display detailed status of the two cooling systems on the Interconnect device. |
interconnect-device name | — | (QFabric systems only) (Optional) Display the status of the cooling zones on the Interconnect device. |
Required Privilege Level
view
Related Documentation
- ACX, EX, M, MX, PTX, QFX, T Series
- show chassis fan
- EX, J, M, MX, PTX, QFX, T Series
- show chassis temperature-thresholds
- QFX Series
- request chassis beacon
List of Sample Output
show chassis zones interconnect-device (QFabric System)show chassis zones (MX2010 Router)
show chassis zones detail (MX2010 Router)
show chassis zones (MX2020 Router)
show chassis zones detail (MX2020 Router)
show chassis beacon interconnect-device (QFabric System)
show chassis beacon interconnect-device fpc (QFabric System)
show chassis beacon node-device (QFabric System)
show chassis beacon node-device fpc (QFabric System)
Output Fields
Table 1 lists the output fields for the show chassis zones command. Output fields are listed in the approximate order in which they appear.
Table 1: show chassis zones Output Fields
Field Name | Field Description |
---|---|
Slot | FPC slot number of the device whose content is being displayed. On QFX3500 standalone switches, the number is always 0. |
Beacon State | Status of the beacon state:
|
show chassis zones command output fields for MX2020 and MX2010 routers: | |
Driving FRU | Field replacable unit (FRU). |
Temperature | Temperature of the specified FRU in degrees Celsius and degrees Fahrenheit. |
Condition | Condition of the specified FRU. Condition can be HIGH TEMP, WARM TEMP, OK, and Offline. |
Num Fans Missing | Number of fans or fan trays missing. |
Num Fans Failed | Number of fans or fan trays that have failed. |
Fan Duty Cycle | Fan duty cycle value. |
show chassis zones detail command output fields for MX2020 and MX2010 routers: | |
Item | Chassis component:
|
Measurement | Fan tray speed utilization in percentage. |
Status | Status of the specified item. Status can be OK, Absent, or Offline. |
Sample Output
show chassis zones interconnect-device (QFabric System)
user@switch> show chassis zones interconnect-device
interconnect1
Slot Beacon State FPC 0 OFF
show chassis zones (MX2010 Router)
user@host> show chassis zones
ZONE 0 Status Driving FRU FPC 6 Temperature 81 degrees C / 177 degrees F Condition HIGH TEMP Num Fans Missing 0 Num Fans Failed 0 Fan Duty Cycle 30 ZONE 1 Status Driving FRU SFB 0 Exhaust-Zone1 Temperature 71 degrees C / 159 degrees F Condition WARM TEMP Num Fans Missing 0 Num Fans Failed 0 Fan Duty Cycle 30
show chassis zones detail (MX2010 Router)
user@host > show chassis zones
ZONE 0 Status Item Status Measurement CB 0 WARM TEMP CB 1 WARM TEMP FPC 0 HIGH TEMP FPC 1 HIGH TEMP FPC 2 WARM TEMP FPC 3 HIGH TEMP FPC 4 HIGH TEMP FPC 5 HIGH TEMP FPC 6 HIGH TEMP FPC 7 HIGH TEMP FPC 8 HIGH TEMP FPC 9 HIGH TEMP ADC 0 WARM TEMP ADC 1 WARM TEMP ADC 2 WARM TEMP ADC 3 WARM TEMP ADC 4 WARM TEMP ADC 5 WARM TEMP ADC 6 WARM TEMP ADC 7 WARM TEMP ADC 8 WARM TEMP ADC 9 WARM TEMP SFB 0 WARM TEMP SFB 1 WARM TEMP SFB 2 WARM TEMP SFB 3 Offline SFB 4 HIGH TEMP SFB 5 WARM TEMP SFB 6 HIGH TEMP SFB 7 WARM TEMP Fan Tray 0 OK Spinning at 98% fan tray speed Fan Tray 1 OK Spinning at 98% fan tray speed ZONE 1 Status Item Status Measurement CB 0 WARM TEMP CB 1 WARM TEMP Routing Engine 0 OK Routing Engine 1 OK SFB 0 WARM TEMP SFB 1 WARM TEMP SFB 2 WARM TEMP SFB 3 Offline SFB 4 HIGH TEMP SFB 5 WARM TEMP SFB 6 HIGH TEMP SFB 7 WARM TEMP SPMB 0 OK SPMB 1 OK Fan Tray 2 OK Spinning at 64% fan tray speed Fan Tray 3 OK Spinning at 64% fan tray speed
show chassis zones (MX2020 Router)
user@host> show chassis zones
ZONE 0 Status Driving FRU FPC 0 Temperature 31 degrees C / 87 degrees F Condition OK Num Fans Missing 0 Num Fans Failed 0 Fan Duty Cycle 30 ZONE 1 Status Driving FRU FPC 19 Temperature 32 degrees C / 89 degrees F Condition OK Num Fans Missing 0 Num Fans Failed 0 Fan Duty Cycle 30
show chassis zones detail (MX2020 Router)
user@host> show chassis zones detail
ZONE 0 Status Item Status Measurement CB 0 OK CB 1 OK FPC 0 OK FPC 1 OK FPC 2 OK FPC 3 OK FPC 4 OK FPC 5 OK FPC 6 OK FPC 7 OK FPC 8 OK FPC 9 OK ADC 0 OK ADC 1 OK ADC 2 OK ADC 3 OK ADC 4 OK ADC 5 OK ADC 6 OK ADC 7 OK ADC 8 OK ADC 9 OK SFB 0 OK SFB 1 OK SFB 2 OK SFB 3 OK SFB 4 OK SFB 5 OK SFB 6 OK SFB 7 OK Fan Tray 0 OK Spinning at 38% fan tray speed Fan Tray 1 OK Spinning at 37% fan tray speed ZONE 1 Status Item Status Measurement CB 0 OK CB 1 OK Routing Engine 0 OK Routing Engine 1 OK FPC 10 OK FPC 11 OK FPC 12 OK FPC 13 OK FPC 14 OK FPC 15 OK FPC 16 OK FPC 17 OK FPC 18 OK FPC 19 OK ADC 10 OK ADC 11 OK ADC 12 OK ADC 13 OK ADC 14 OK ADC 15 OK ADC 16 OK ADC 17 OK ADC 18 OK ADC 19 OK SFB 0 OK SFB 1 OK SFB 2 OK SFB 3 OK SFB 4 OK SFB 5 OK SFB 6 OK SFB 7 OK SPMB 0 OK SPMB 1 OK Fan Tray 2 OK Spinning at 38% fan tray speed Fan Tray 3 OK Spinning at 38% fan tray speed
show chassis beacon interconnect-device (QFabric System)
user@switch> show chassis beacon interconnect-device
interconnect1
Chassis OFF CB 0 OFF CB 1 OFF FC 0 FPC 0 OFF FC 1 FPC 1 OFF RC 0 FPC 8 OFF RC 1 FPC 9 OFF
show chassis beacon interconnect-device fpc (QFabric System)
user@switch> show chassis beacon interconnect-device
interconnect1 fpc 0
FPC 0 ON
show chassis beacon node-device (QFabric System)
user@switch> show chassis beacon node-device
node1
node1 ON
show chassis beacon node-device fpc (QFabric System)
user@switch> show chassis beacon node-device
node1 fpc 0
FPC 0 ON
Published: 2013-08-15