show interfaces ps0 (Pseudowire Subscriber Interfaces)

Syntax

show interfaces ps0<brief | detail | extensive | terse>

Release Information

Command introduced at Junos OS Release 13.1.

Description

Display status information about the pseudowire subscriber interface.

Options

brief | detail | extensive | terse

(Optional) Display the specified level of output.

Required Privilege Level

view

List of Sample Output

show interfaces ps0

Output Fields

Table 1 lists the output fields for the show interfaces ps0 command. Output fields are listed in the approximate order in which they appear.

Table 1: show interfaces ps0 Output Fields

Field Name

Field Description

Level of Output

Physical Interface 

Physical interface

Name of the physical interface.

brief detail extensive none

Enabled

State of the interface. Possible values are described in the “Enabled Field” section under Common Output Fields Description.

brief detail extensive none

Interface index

Physical interface index number, which reflects its initialization sequence.

detail extensive none

SNMP ifIndex

SNMP index number for the physical interface.

detail extensive none

Type

Physical interface type (Software-Pseudo).

brief detail extensive none

Link-level type

Encapsulation being used on the physical interface.

brief detail extensive

MTU

MTU size on the physical interface.

brief detail extensive

Clocking

Reference clock source. It can be Internal or External.

brief detail extensive

Speed

Speed at which the interface is running.

brief detail extensive

Device flags

Information about the physical device. Possible values are described in the “Device Flags” section under Common Output Fields Description.

brief detail extensive none

Interface flags

Information about the interface. Possible values are described in the “Interface Flags” section under Common Output Fields Description.

brief detail extensive none

Current address

Configured MAC address.

detail extensive none

Hardware address

MAC address of the hardware.

detail extensive none

Last flapped

Date, time, and how long ago the interface went from down to up or up to down. The format is Last flapped: year-month-day hours:minutes:seconds: timezone (hours:minutes:seconds ago). or Never. For example, Last flapped: 2002-04-26 10:52:40 PDT (04:33:20 ago).

detail extensive none

input packets

Number of packets received on the logical interface.

detail extensive none

output packets

Number of packets transmitted on the logical interface.

detail extensive none

Logical Interface 

Logical interface

Name of the logical interface.

brief detail extensive none

Index

Logical interface index number (which reflects its initialization sequence).

detail extensive none

SNMP ifIndex

Logical interface SNMP interface index number.

detail extensive none

Flags

Information about the logical interface. Possible values are described in the “Logical Interface Flags” section under Common Output Fields Description.

brief detail extensive none

Encapsulation

Type of encapsulation configured on the logical interface.

brief extensive none

Input packets

Number of packets received on the logical interface.

none

Output packets

Number of packets transmitted on the logical interface.

none

Protocol

Protocol family configured on the logical interface.

detail extensive none

MTU

MTU size on the logical interface.

detail extensive none

Flags

Information about the protocol family flags. Possible values are described in the “Family Flags” section under Common Output Fields Description.

detail extensive none

Addresses, Flags

Information about the addresses configured for the protocol family. Possible values are described in the “Addresses Flags” section under Common Output Fields Description.

detail extensive none

Destination

IP address of the remote side of the connection.

detail extensive none

Local

IP address of the logical interface.

detail extensive terse none

Broadcast

Broadcast address.

detail extensive none

Sample Output

show interfaces ps0

user@host> show interfaces ps0
Physical interface: ps0, Enabled, Physical link is Up
 Interface index: 166, SNMP ifIndex: 658
 Type: Software-Pseudo, Link-level type: 90, MTU: 1518, Clocking: 1, Speed: 800mbps
 Device flags : Present Running
 Interface flags: Point-To-Point Internal: 0x4000
 Current address: 00:1d:b5:a8:19:4a, Hardware address: 00:1d:b5:a8:19:4a
 Last flapped : Never
  Input packets : 0
  Output packets: 0

 Logical interface ps0.0 (Index 74) (SNMP ifIndex 656)
  Flags: Point-To-Point 0x4000 Encapsulation: Ethernet-CCC
  Input packets : 482
  Output packets: 0
  Protocol ccc, MTU: 1518
   Flags: Is-Primary

 Logical interface ps0.1 (Index 78) (SNMP ifIndex 665)
  Flags: Point-To-Point 0x4000 VLAN-Tag [ 0x8100.100 ] Encapsulation: ENET2
  Input packets : 0
  Output packets: 482
  Protocol inet, MTU: 1500
   Flags: Sendbcast-pkt-to-re
    Addresses, Flags: Is-Preferred Is-Primary
     Destination: 20.0.0/24, Local: 20.0.0.1, Broadcast: 20.0.0.255

 Logical interface ps0.32767 (Index 75) (SNMP ifIndex 692)
  Flags: Point-To-Point 0x4000 VLAN-Tag [ 0x0000.0 ] Encapsulation: ENET2
  Input packets : 0
  Output packets: 0