Supported Platforms
temps
Syntax
temps -T target
Release Information
Command supported by Junos OS Release 9.1 and later.
Description
(JCS1200 platform only) Show temperature information (in degrees Fahrenheit) for components in the JCS chassis. This information is useful for viewing current temperature values and temperature threshold settings.
Options
-T target—Specify the target of the temps command. Valid targets for this command are:
- system:blade[x]—Specify a Routing Engine as the command target. Replace x with the Routing Engine slot number (1 through 12).
- system:switch[x]—Specify a JCS switch module as the command target. Replace x with the switch number (1 or 2).
- system:mm[x]—Specify a JCS management module as the command target. Replace x with the primary management module number (1 or 2).
Required Privilege Level
operator (display)
List of Sample Output
temps (Routing Engine)temps (JCS Management Module)
Output Fields
Table 1 lists the output fields for the temps command. Output fields are listed in the approximate order in which they appear.
Table 1: temps Output Fields
Field Name | Field Description |
---|---|
Value | Current temperature (in degrees Fahrenheit) of the component. |
Warning | Temperature at which a warning message occurs. |
Reset | Temperature at which the component will reset. |
Hysteresis | The amount the temperature must decrease below the Warning threshold before the warning is cleared. |
Sample Output
temps (Routing Engine)
system> temps -T system:blade[3]
Component Value Warning Reset Hysteresis CPU1 38.00 85.00 95.00 (7.00) CPU2 35.00 85.00 95.00 (7.00)
temps (JCS Management Module)
system> temps -T system:mm[2]
Component Value Warning Reset Hysteresis MM Ambient 43.00 60.00 55.00 (5.00)