oam-on-svlan (Ethernet Interfaces)

Syntax

oam-on-svlan;

Hierarchy Level

[edit interfaces interface-name]

Release Information

Statement introduced in Junos OS Release 13.1.

Description

On MX Series routers with MPC/MIC interfaces, enable propagation of the Ethernet IEEE 802.1ag Operation, Administration, and Maintenance (OAM) state of a static single-tagged service VLAN (S-VLAN) logical interface to the dynamic or static double-tagged customer VLAN (C-VLAN) logical interface and associated subscriber interfaces configured on the S-VLAN. The static S-VLAN logical interface must be configured with Ethernet OAM connectivity fault management (CFM) on a Gigabit Ethernet, 10-Gigabit Ethernet, or aggregated Ethernet physical interface. The C-VLAN logical interface must have the same S-VLAN (outer) tag as the S-VLAN logical interface.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Published: 2013-02-12