Configuring the Power-On Sequence for FPCs on T640, T1600, and T4000 Routers
Starting with Junos OS Release 12.3, you can configure the power-on sequence for the Flexible PIC Concentrators (FPCs) on T640, T1600, and T4000 routers. This configuration enables you to redistribute the available power to the FPCs on the basis of your requirements and the calculated power consumption of the FPCs.
To configure the power-on sequence:
- At the [edit chassis] hierarchy level, configure
the fru-poweron-sequence statement indicating the order
in which the FPCs need to be powered on.[edit chassis]user@host# set fru-poweron-sequence fru-poweron-sequence
For example:
[edit chassis]user@host# set fru-poweron-sequence “0 2 1” - Verify the configuration by using the show command
at the [edit chassis] hierarchy level:
[edit chassis] user@host# show fru-poweron-sequence "0 2 1";
![]() |
|