Example: Configuring a JCS1200 Platform and a Single T Series Router

In this configuration example, the JCS1200 platform is connected to a single T640 router. The configuration is described in the following sections:

Requirements

This configuration example requires the following hardware and software components:

  • Junos OS Release 9.1 or later
  • JCS1200 platform with Routing Engines in slots 1, 2, 3, and 4
  • T640 router with FPCs in slots 0, 1, 2, and 3

Overview

This example configures the JCS1200 platform and one connected T640 router. For this example, you need to configure a single Root System Domain (RSD), create Protected System Domains (PSDs), and assign Routing Engines in the JCS chassis and Flexible PIC Controllers (FPCs) on the T640 router to each PSD as follows:

  • PSD1—Routing Engines in slots 1 and 2 on the JCS chassis and FPCs in slots 0, 1, and 2 on the T640 router
  • PSD2—Routing Engines in slots 3 and 4 on the JCS chassis and the FPC in slot 3 on the T640 router

Configuration

First, configure the Routing Engines on the JCS1200 platform using the management module command-line interface (CLI). Then, configure the T640 router using the Junos OS CLI.

JCS1200 Platform Configuration

Step-by-Step Procedure

To configure the parameters required for the Routing Engines in the JCS chassis:

  1. Log in to the JCS management module.
  2. Assign the Routing Engines in slots 1 (primary) and 2 (backup) to RSD1 and PSD1:
    system> baydata —b 01 —data “V01–JCS01–SD01–PSD01–REP01–REB02–PRDT640”
    system> baydata —b 02 —data “V01–JCS01–SD01–PSD01–REP01–REB02–PRDT640”
  3. Assign Routing Engines in slots 3 (primary) and 4 (backup) to RSD1 and PSD2:
    system> baydata —b 03 —data “V01–JCS01–SD01–PSD02–REP03–REB04–PRDT640”
    system> baydata —b 04 —data “V01–JCS01–SD01–PSD02–REP03–REB04–PRDT640”

    The baydata command specifies the target as a bay blade (-b), identifies the blade (Routing Engine) slot, and specifies the following parameters:

    • V—Product version.
    • JCS—JCS platform identifier.
    • SD—RSD identifier.
    • PSD—PSD identifier.
    • REP—Slot in which the primary (or master) Routing Engine resides.
    • REB—Slot in which the backup Routing Engine resides.
    • PRD—Juniper Networks router product.

Results

Display the results of the configuration:

system> baydata
Bay  Status            Definition
1    Supported         V01–JCS01–SD01–PSD01–REP01–REB02–PRDT640
2    Supported         V01-JCS01-SD01-PSD01-REP01-REB02-PRDT640
3    Supported         V01-JCS01-SD01-PSD02-REP03-REB04-PRDT640
4    Supported         V01-JCS01-SD01-PSD02-REP03-REB04-PRDT640
5    No blade present
6    No blade present
7    No blade present
8    No blade present
9    No blade present
10   No blade present
11   No blade present
12   No blade present

T640 Router Configuration

Step-by-Step Procedure

To configure the RSD and create the PSDs on the T640 router:

  1. At the [edit chassis system-domains] hierarchy level of the Junos OS CLI, include the root-domain-id 1 statement to identify the RSD.
  2. At the [edit chassis system-domains] hierarchy level, include the protected-system-domains psd1 statement to create PSD1.
  3. At the [edit chassis system-domains protected-system-domains psd1] hierarchy level:
    1. Include the fpcs 0 fpcs 1 fpcs 2 statement to assign the FPCs in slots 0, 1, and 2 to PSD1.
    2. Include the control-system-id 1 statement to identify the JCS1200 platform.
    3. Include the control-slot-numbers 1 control-slot-numbers 2 statement to assign the Routing Engines in slots 1 and 2 in the JCS chassis to PSD1.
  4. At the [edit chassis system-domains] hierarchy level, include the protected-system-domains psd2 statement to create PSD2.
  5. At the [edit chassis system-domains protected-system-domains psd2] hierarchy level:
    1. Include the fpcs 3 statement to assign the FPC in slot 3 to PSD2.
    2. Include the control-system-id 1 statement to identify the JCS1200 platform.
    3. Include the control-slot-numbers 3 control-slot-numbers 4 statement to assign the Routing Engines in slots 3 and 4 in the JCS chassis to PSD2.

Results

Display the results of the configuration:

system-domains {root-domain-id 1;protected-system-domains {psd1 {description “psd for customer1”;fpcs [ 0 1 2 ];control-system-id 1;control-slot-numbers [ 1 2 ];}psd2 {description “psd for customer2”;fpcs [ 3 ];control-system-id 1;control-slot-numbers [ 3 4 ];}}}

Verification

Verify the status of the RSD and PSDs:

Verifying Configured PSDs

Purpose

Verify that the PSDs configured under the RSD are online.

Action

On the RSD, issue the show psd command:

user@rsd1> show chassis psd
PSD  Description         State               Uptime
 1   psd for customer1   Online              1 hour, 12 minutes, 15 seconds
 2   psd for customer2   Online              1 hour, 12 minutes, 15 seconds

Meaning

PSD1 and PSD2 are configured and online.

Verifying PSD Hardware

Purpose

Verify that each PSD has been assigned the correct FPCs on the T640 router and the appropriate Routing Engines on the JCS1200 platform.

Action

Issue the show chassis hardware command:

PSD1

user@psd1> show chassis hardware
rsd-re0:
--------------------------------------------------------------------------

Hardware inventory:
Item             Version  Part number  Serial number     Description
Chassis                                S19068            T1600
Midplane         REV 04   710-002726   AX5666            T640 Backplane
CIP              REV 05   710-002895   HC0474            T Series CIP
PEM 0            Rev 06   740-017906   TE27806           Power Entry Module 3x80
SCG 0            REV 04   710-003423   HF6042            T640 Sonet Clock Gen.
SCG 1            REV 11   710-003423   HW7765            T640 Sonet Clock Gen.
Routing Engine 0 REV 04   740-014082   1000660098        RE-A-2000
Routing Engine 1 REV 01   740-005022   210865700324      RE-3.0
CB 0             REV 06   710-007655   WE9377            Control Board (CB-T)
CB 1             REV 06   710-007655   WE9379            Control Board (CB-T)
FPC 0            REV 07   710-013035   DN5856            FPC Type 3-ES
  CPU            REV 07   710-016744   DM3593            ST-PMB2
  PIC 0          REV 05   750-007141   HG2427            10x 1GE(LAN), 1000 BASE
    Xcvr 1       REV 01   740-011613   P9F15ZN           SFP-SX
    Xcvr 2       REV 01   740-011613   P9F11CC           SFP-SX
    Xcvr 3       REV 01   740-011613   P9F1AM1           SFP-SX
    Xcvr 4       REV 01   740-011613   P9F11X1           SFP-SX
    Xcvr 5       REV 01   740-011613   P9F1715           SFP-SX
  PIC 1          REV 01   750-004695   HD5978            1x Tunnel
  PIC 2          REV 05   750-004695   HT4383            1x Tunnel
  MMB 0          REV 04   710-016036   DN6989            ST-MMB2
FPC 1            REV 05   710-010157   HR5838            E-FPC Type 2
  CPU            REV 01   710-010169   HN3431            FPC CPU-Enhanced
  PIC 0          REV 07   750-001900   AT1697            1x OC-48 SONET, SMSR
  PIC 1          REV 08   750-009066   NA0423            1x OC-48 SONET SFP
    Xcvr 0       REV 01   740-011785   PAQ0Z8C           SFP-SR
  PIC 2          REV 11   750-003737   NA2450            4x G/E, 1000 BASE-SX
  PIC 3          REV 05   750-001850   WD3132            1x Tunnel
  MMB 1          REV 01   710-010171   HN6495            MMB-288mbit
FPC 2            REV 04   710-013558   JP3361            E2-FPC Type 2
  CPU            REV 02   710-013563   JN4128            FPC CPU-Enhanced
  PIC 0          REV 07   750-010618   CZ6647            4x G/E SFP, 1000 BASE
    Xcvr 0       REV 01   740-011613   P8E2SSM           SFP-SX
    Xcvr 1       REV 01   740-011782   P8C29XQ           SFP-SX
    Xcvr 2       REV 01   740-011782   P86218N           SFP-SX
    Xcvr 3       REV 01   740-011782   PB82CR5           SFP-SX
  PIC 2          REV 16   750-008155   NB8516            2x G/E IQ, 1000 BASE
    Xcvr 0       REV 01   740-007326   P11WLS9           SFP-SX
    Xcvr 1       REV 01   740-011613   PAM2Y9G           SFP-SX
  PIC 3          REV 16   750-008155   ND7764            2x G/E IQ, 1000 BASE
    Xcvr 0       REV 01   740-011782   PBA29H8           SFP-SX
  MMB 1          REV 05   710-010171   JP5579            MMB-5M3-288mbit
SPMB 0           REV 10   710-003229   WE9582            T Series Switch CPU
SPMB 1           REV 10   710-003229   WE9587            T Series Switch CPU
SIB 0            REV 05   710-013074   DB2624            SIB-I8-SF
SIB 1            REV 05   710-013074   DE7881            SIB-I8-SF
SIB 2            REV 05   710-013074   DE7889            SIB-I8-SF
SIB 3            REV 05   710-013074   DE9972            SIB-I8-SF
SIB 4            REV 05   710-013074   DE7937            SIB-I8-SF
Fan Tray 0                                               Front Top Fan Tray
Fan Tray 1                                               Front Bottom Fan Tray
Fan Tray 2                                               Rear Fan Tray

psd1-re0:
--------------------------------------------------------------------------
Hardware inventory:
Item             Version  Part number  Serial number     Description
Chassis                   740-023156   SNJCSJCSAC00      JCS1200 AC Chassis
Routing Engine 1 REV 01   740-023157   SNBLJCSAC005      RE-JCS1200-1x2330
Routing Engine 2 REV 01   740-023158   SNBLJCSAC006      RE-JCS1200-1x2330

PSD2

user@psd2> show chassis hardware
rsd-re0:
--------------------------------------------------------------------------
Hardware inventory:
Item             Version  Part number  Serial number     Description
Chassis                                S19068            T1600
Midplane         REV 04   710-002726   AX5666            T640 Backplane
CIP              REV 05   710-002895   HC0474            T Series CIP
PEM 0            Rev 06   740-017906   TE27806           Power Entry Module 3x80
SCG 0            REV 04   710-003423   HF6042            T640 Sonet Clock Gen.
SCG 1            REV 11   710-003423   HW7765            T640 Sonet Clock Gen.
Routing Engine 0 REV 04   740-014082   1000660098        RE-A-2000
Routing Engine 1 REV 01   740-005022   210865700324      RE-3.0
CB 0             REV 06   710-007655   WE9377            Control Board (CB-T)
CB 1             REV 06   710-007655   WE9379            Control Board (CB-T)
FPC 3            REV 01   710-013560   JE4851            E2-FPC Type 3
  CPU            REV 05   710-010169   HX8637            FPC CPU-Enhanced
  MMB 0          REV 04   710-010171   HX7130            MMB-5M3-288mbit
  MMB 1          REV 04   710-010171   HX9460            MMB-5M3-288mbit
SPMB 0           REV 10   710-003229   WE9582            T Series Switch CPU
SPMB 1           REV 10   710-003229   WE9587            T Series Switch CPU
SIB 0            REV 05   710-013074   DB2624            SIB-I8-SF
SIB 1            REV 05   710-013074   DE7881            SIB-I8-SF
SIB 2            REV 05   710-013074   DE7889            SIB-I8-SF
SIB 3            REV 05   710-013074   DE9972            SIB-I8-SF
SIB 4            REV 05   710-013074   DE7937            SIB-I8-SF
Fan Tray 0                                               Front Top Fan Tray
Fan Tray 1                                               Front Bottom Fan Tray
Fan Tray 2                                               Rear Fan Tray

psd2-re0:
--------------------------------------------------------------------------
Hardware inventory:
Item             Version  Part number  Serial number     Description
Chassis                   740-023156   SNJCSJCSAC00      JCS1200 AC Chassis
Routing Engine 3 REV 01   740-023160   SNBLJCSAC007      RE-JCS1200-1x2330
Routing Engine 4 REV 01   740-023161   SNBLJCSAC008      RE-JCS1200-1x2330

Meaning

On PSD1, under the rsd-re0 heading, you can see that PSD1 owns the FPCs in slots 0, 1, and 2 in the T640 chassis. Under the psd1-re0 output field, the output indicates that the Routing Engines in slots 1 and 2 in the JCS chassis are assigned to PSD1.

On PSD2, under the rsd-re0 heading, you can see that PSD2 owns the FPC in slot 3 in the T640 chassis. Under the psd2-re0 output field, the output indicates that the Routing Engines in slots 3 and 4 in the JCS chassis are assigned to PSD2.