Supported Platforms
Example: Configuring a JCS1200 Platform and a Single T Series Router
In this configuration example, the JCS1200 platform is connected to a single T640 router. The configuration is described in the following sections:
Requirements
This configuration example requires the following hardware and software components:
- Junos OS Release 9.1 or later
- JCS1200 platform with Routing Engines in slots 1, 2, 3, and 4
- T640 router with FPCs in slots 0, 1, 2, and 3
Overview
This example configures the JCS1200 platform and one connected T640 router. For this example, you need to configure a single Root System Domain (RSD), create Protected System Domains (PSDs), and assign Routing Engines in the JCS chassis and Flexible PIC Controllers (FPCs) on the T640 router to each PSD as follows:
- PSD1—Routing Engines in slots 1 and 2 on the JCS chassis and FPCs in slots 0, 1, and 2 on the T640 router
- PSD2—Routing Engines in slots 3 and 4 on the JCS chassis and the FPC in slot 3 on the T640 router
Configuration
First, configure the Routing Engines on the JCS1200 platform using the management module command-line interface (CLI). Then, configure the T640 router using the Junos OS CLI.
JCS1200 Platform Configuration
Step-by-Step Procedure
To configure the parameters required for the Routing Engines in the JCS chassis:
- Log in to the JCS management module.
- Assign the Routing Engines in slots 1 (primary) and 2
(backup) to RSD1 and PSD1:
system> baydata —b 01 —data “V01–JCS01–SD01–PSD01–REP01–REB02–PRDT640”
system> baydata —b 02 —data “V01–JCS01–SD01–PSD01–REP01–REB02–PRDT640”
- Assign Routing Engines in slots 3 (primary) and 4 (backup)
to RSD1 and PSD2:
system> baydata —b 03 —data “V01–JCS01–SD01–PSD02–REP03–REB04–PRDT640”
system> baydata —b 04 —data “V01–JCS01–SD01–PSD02–REP03–REB04–PRDT640”
The baydata command specifies the target as a bay blade (-b), identifies the blade (Routing Engine) slot, and specifies the following parameters:
- V—Product version.
- JCS—JCS platform identifier.
- SD—RSD identifier.
- PSD—PSD identifier.
- REP—Slot in which the primary (or master) Routing Engine resides.
- REB—Slot in which the backup Routing Engine resides.
- PRD—Juniper Networks router product.
Results
Display the results of the configuration:
system> baydata
Bay Status Definition 1 Supported V01–JCS01–SD01–PSD01–REP01–REB02–PRDT640 2 Supported V01-JCS01-SD01-PSD01-REP01-REB02-PRDT640 3 Supported V01-JCS01-SD01-PSD02-REP03-REB04-PRDT640 4 Supported V01-JCS01-SD01-PSD02-REP03-REB04-PRDT640 5 No blade present 6 No blade present 7 No blade present 8 No blade present 9 No blade present 10 No blade present 11 No blade present 12 No blade present
T640 Router Configuration
Step-by-Step Procedure
To configure the RSD and create the PSDs on the T640 router:
- At the [edit chassis system-domains] hierarchy level of the Junos OS CLI, include the root-domain-id 1 statement to identify the RSD.
- At the [edit chassis system-domains] hierarchy level, include the protected-system-domains psd1 statement to create PSD1.
- At the [edit chassis system-domains protected-system-domains psd1] hierarchy level:
- Include the fpcs 0 fpcs 1 fpcs 2 statement to assign the FPCs in slots 0, 1, and 2 to PSD1.
- Include the control-system-id 1 statement to identify the JCS1200 platform.
- Include the control-slot-numbers 1 control-slot-numbers 2 statement to assign the Routing Engines in slots 1 and 2 in the JCS chassis to PSD1.
- At the [edit chassis system-domains] hierarchy level, include the protected-system-domains psd2 statement to create PSD2.
- At the [edit chassis system-domains protected-system-domains psd2] hierarchy level:
- Include the fpcs 3 statement to assign the FPC in slot 3 to PSD2.
- Include the control-system-id 1 statement to identify the JCS1200 platform.
- Include the control-slot-numbers 3 control-slot-numbers 4 statement to assign the Routing Engines in slots 3 and 4 in the JCS chassis to PSD2.
Results
Display the results of the configuration:
Verification
Verify the status of the RSD and PSDs:
Verifying Configured PSDs
Purpose
Verify that the PSDs configured under the RSD are online.
Action
On the RSD, issue the show psd command:
user@rsd1> show chassis psd
PSD Description State Uptime 1 psd for customer1 Online 1 hour, 12 minutes, 15 seconds 2 psd for customer2 Online 1 hour, 12 minutes, 15 seconds
Meaning
PSD1 and PSD2 are configured and online.
Verifying PSD Hardware
Purpose
Verify that each PSD has been assigned the correct FPCs on the T640 router and the appropriate Routing Engines on the JCS1200 platform.
Action
Issue the show chassis hardware command:
PSD1
user@psd1> show chassis hardware
rsd-re0: -------------------------------------------------------------------------- Hardware inventory: Item Version Part number Serial number Description Chassis S19068 T1600 Midplane REV 04 710-002726 AX5666 T640 Backplane CIP REV 05 710-002895 HC0474 T Series CIP PEM 0 Rev 06 740-017906 TE27806 Power Entry Module 3x80 SCG 0 REV 04 710-003423 HF6042 T640 Sonet Clock Gen. SCG 1 REV 11 710-003423 HW7765 T640 Sonet Clock Gen. Routing Engine 0 REV 04 740-014082 1000660098 RE-A-2000 Routing Engine 1 REV 01 740-005022 210865700324 RE-3.0 CB 0 REV 06 710-007655 WE9377 Control Board (CB-T) CB 1 REV 06 710-007655 WE9379 Control Board (CB-T) FPC 0 REV 07 710-013035 DN5856 FPC Type 3-ES CPU REV 07 710-016744 DM3593 ST-PMB2 PIC 0 REV 05 750-007141 HG2427 10x 1GE(LAN), 1000 BASE Xcvr 1 REV 01 740-011613 P9F15ZN SFP-SX Xcvr 2 REV 01 740-011613 P9F11CC SFP-SX Xcvr 3 REV 01 740-011613 P9F1AM1 SFP-SX Xcvr 4 REV 01 740-011613 P9F11X1 SFP-SX Xcvr 5 REV 01 740-011613 P9F1715 SFP-SX PIC 1 REV 01 750-004695 HD5978 1x Tunnel PIC 2 REV 05 750-004695 HT4383 1x Tunnel MMB 0 REV 04 710-016036 DN6989 ST-MMB2 FPC 1 REV 05 710-010157 HR5838 E-FPC Type 2 CPU REV 01 710-010169 HN3431 FPC CPU-Enhanced PIC 0 REV 07 750-001900 AT1697 1x OC-48 SONET, SMSR PIC 1 REV 08 750-009066 NA0423 1x OC-48 SONET SFP Xcvr 0 REV 01 740-011785 PAQ0Z8C SFP-SR PIC 2 REV 11 750-003737 NA2450 4x G/E, 1000 BASE-SX PIC 3 REV 05 750-001850 WD3132 1x Tunnel MMB 1 REV 01 710-010171 HN6495 MMB-288mbit FPC 2 REV 04 710-013558 JP3361 E2-FPC Type 2 CPU REV 02 710-013563 JN4128 FPC CPU-Enhanced PIC 0 REV 07 750-010618 CZ6647 4x G/E SFP, 1000 BASE Xcvr 0 REV 01 740-011613 P8E2SSM SFP-SX Xcvr 1 REV 01 740-011782 P8C29XQ SFP-SX Xcvr 2 REV 01 740-011782 P86218N SFP-SX Xcvr 3 REV 01 740-011782 PB82CR5 SFP-SX PIC 2 REV 16 750-008155 NB8516 2x G/E IQ, 1000 BASE Xcvr 0 REV 01 740-007326 P11WLS9 SFP-SX Xcvr 1 REV 01 740-011613 PAM2Y9G SFP-SX PIC 3 REV 16 750-008155 ND7764 2x G/E IQ, 1000 BASE Xcvr 0 REV 01 740-011782 PBA29H8 SFP-SX MMB 1 REV 05 710-010171 JP5579 MMB-5M3-288mbit SPMB 0 REV 10 710-003229 WE9582 T Series Switch CPU SPMB 1 REV 10 710-003229 WE9587 T Series Switch CPU SIB 0 REV 05 710-013074 DB2624 SIB-I8-SF SIB 1 REV 05 710-013074 DE7881 SIB-I8-SF SIB 2 REV 05 710-013074 DE7889 SIB-I8-SF SIB 3 REV 05 710-013074 DE9972 SIB-I8-SF SIB 4 REV 05 710-013074 DE7937 SIB-I8-SF Fan Tray 0 Front Top Fan Tray Fan Tray 1 Front Bottom Fan Tray Fan Tray 2 Rear Fan Tray psd1-re0: -------------------------------------------------------------------------- Hardware inventory: Item Version Part number Serial number Description Chassis 740-023156 SNJCSJCSAC00 JCS1200 AC Chassis Routing Engine 1 REV 01 740-023157 SNBLJCSAC005 RE-JCS1200-1x2330 Routing Engine 2 REV 01 740-023158 SNBLJCSAC006 RE-JCS1200-1x2330
PSD2
user@psd2> show chassis hardware
rsd-re0: -------------------------------------------------------------------------- Hardware inventory: Item Version Part number Serial number Description Chassis S19068 T1600 Midplane REV 04 710-002726 AX5666 T640 Backplane CIP REV 05 710-002895 HC0474 T Series CIP PEM 0 Rev 06 740-017906 TE27806 Power Entry Module 3x80 SCG 0 REV 04 710-003423 HF6042 T640 Sonet Clock Gen. SCG 1 REV 11 710-003423 HW7765 T640 Sonet Clock Gen. Routing Engine 0 REV 04 740-014082 1000660098 RE-A-2000 Routing Engine 1 REV 01 740-005022 210865700324 RE-3.0 CB 0 REV 06 710-007655 WE9377 Control Board (CB-T) CB 1 REV 06 710-007655 WE9379 Control Board (CB-T) FPC 3 REV 01 710-013560 JE4851 E2-FPC Type 3 CPU REV 05 710-010169 HX8637 FPC CPU-Enhanced MMB 0 REV 04 710-010171 HX7130 MMB-5M3-288mbit MMB 1 REV 04 710-010171 HX9460 MMB-5M3-288mbit SPMB 0 REV 10 710-003229 WE9582 T Series Switch CPU SPMB 1 REV 10 710-003229 WE9587 T Series Switch CPU SIB 0 REV 05 710-013074 DB2624 SIB-I8-SF SIB 1 REV 05 710-013074 DE7881 SIB-I8-SF SIB 2 REV 05 710-013074 DE7889 SIB-I8-SF SIB 3 REV 05 710-013074 DE9972 SIB-I8-SF SIB 4 REV 05 710-013074 DE7937 SIB-I8-SF Fan Tray 0 Front Top Fan Tray Fan Tray 1 Front Bottom Fan Tray Fan Tray 2 Rear Fan Tray psd2-re0: -------------------------------------------------------------------------- Hardware inventory: Item Version Part number Serial number Description Chassis 740-023156 SNJCSJCSAC00 JCS1200 AC Chassis Routing Engine 3 REV 01 740-023160 SNBLJCSAC007 RE-JCS1200-1x2330 Routing Engine 4 REV 01 740-023161 SNBLJCSAC008 RE-JCS1200-1x2330
Meaning
On PSD1, under the rsd-re0 heading, you can see that PSD1 owns the FPCs in slots 0, 1, and 2 in the T640 chassis. Under the psd1-re0 output field, the output indicates that the Routing Engines in slots 1 and 2 in the JCS chassis are assigned to PSD1.
On PSD2, under the rsd-re0 heading, you can see that PSD2 owns the FPC in slot 3 in the T640 chassis. Under the psd2-re0 output field, the output indicates that the Routing Engines in slots 3 and 4 in the JCS chassis are assigned to PSD2.