Supported Platforms
show oam ethernet connectivity-fault-management mep-database
Syntax
Release Information
Command introduced in Junos OS Release 10.2 for EX Series switches.
Description
Display IEEE 802.1ag Operation, Administration, and Management (OAM) connectivity fault management (CFM) database information for CFM maintenance association end points (MEPs) in a CFM session.
Options
maintenance-association ma-name | — | Display connectivity fault management information for the specified maintenance association. |
maintenance-domain domain-name | — | Display connectivity fault management information for the specified maintenance domain. |
local-mep local-mep-id | — | (Optional) Display connectivity fault management information for the specified local MEP only. |
remote-mep remote-mep-id | — | (Optional) Display connectivity fault management information for the specified remote MEP only. |
Required Privilege Level
view
List of Sample Output
show oam ethernet connectivity-fault-management mep-databaseshow oam ethernet connectivity-fault-management mep-database local-mep remote-mep
show oam ethernet connectivity-fault-management mep-database remote-mep (Action Profile Event)
Output Fields
Table 1 lists the output fields for the show oam ethernet connectivity-fault-management mep-database command. Output fields are listed in the approximate order in which they appear.
Table 1: show oam ethernet connectivity-fault-management mep-database Output Fields
Field Name | Field Description |
---|---|
Maintenance domain name | Maintenance domain name. |
Format (Maintenance domain) | Maintenance domain name format configured. |
Level | Maintenance domain level configured. |
Maintenance association name | Maintenance association name. |
Format (Maintenance association) | Maintenance association name format configured. |
Continuity-check status | Continuity-check status. |
Interval | Continuity-check message interval. |
MEP identifier | Maintenance association end point (MEP) identifier. |
Direction | MEP direction configured. |
MAC address | MAC address configured for the MEP. |
Auto-discovery | Whether automatic discovery is enabled or disabled. |
Priority | Priority used for CCMs and linktrace messages transmitted by the MEP. |
Interface name | Interface identifier. |
Interface status | Local interface status. |
Link status | Local link status. |
Remote MEP not receiving CCM | Whether the remote MEP is not receiving CCMs. |
Erroneous CCM received | Whether erroneous CCMs have been received. |
Cross-connect CCM received | Whether cross-connect CCMs have been received. |
RDI sent by some MEP | Whether the remote defect indication (RDI) bit is set in messages that have been received. The absence of the RDI bit in a CCM indicates that the transmitting MEP is receiving CCMs from all configured MEPs. |
CCMs sent | Number of CCMs transmitted. |
CCMs received out of sequence | Number of CCMs received out of sequence. |
LBMs sent | Number of loopback messages (LBMs) sent. |
Valid in-order LBRs received | Number of loopback response messages (LBRs) received that were valid messages and in sequence. |
Valid out-of-order LBRs received | Number of LBRs received that were valid messages and not in sequence. |
LBRs received with corrupted data | Number of LBRs received that were corrupted. |
LBRs sent | Number of LBRs transmitted. |
LTMs sent | Linktrace messages (LTMs) transmitted. |
LTMs received | Linktrace messages received. |
LTRs sent | Linktrace responses (LTRs) transmitted. |
LTRs received | Linktrace responses received. |
Sequence number of next LTM request | Sequence number of the next linktrace message request to be transmitted. |
1DMs sent | If the MEP is an initiator for a one-way ETH-DM session: Number of one-way delay measurement (1DM) PDU frames sent to the peer MEP in this session. For all other cases, this field displays 0. |
Valid 1DMs received | If the MEP is a receiver for a one-way ETH-DM session: Number of valid 1DM frames received. For all other cases, this field displays 0. |
Invalid 1DMs received | If the MEP is a receiver for a one-way ETH-DM session: Number of invalid 1DM frames received. For all other cases, this field displays 0. |
DMMs sent | If the MEP is an initiator for a two-way ETH-DM session: Number of Delay Measurement Message (DMM) PDU frames sent to the peer MEP in this session. For all other cases, this field displays 0. |
DMRs sent | If the MEP is a responder for a ETH-DM session: Number of Delay Measurement Reply (DMR) frames sent. For all other cases, this field displays 0. |
Valid DMRs received | If the MEP is an initiator for a two-way ETH-DM session: Number of valid DMRs received. For all other cases, this field displays 0. |
Invalid DMRs received | If the MEP is an initiator for a two-way ETH-DM session: Number of invalid DMRs received. For all other cases, this field displays 0. |
Remote MEP identifier | MEP identifier of the remote MEP. |
State (remote MEP) | State of the remote MEP: idle, start, ok, or failed. |
MAC address | MAC address of the remote MEP. |
Type | Whether the remote MEP MAC address was learned using automatic discovery or configured. |
Interface | Interface of the remote MEP. A seven-digit number is appended if CFM is configured to run on a routing instance of type VPLS. |
Last flapped | Date, time, and how long ago the remote MEP interface went from down to up. The format is Last flapped: year-month-day hours:minutes:seconds timezone (hours:minutes:seconds ago). For example, Last flapped: 2002-04-26 10:52:40 PDT (04:33:20 ago). |
Remote defect indication | Whether the remote defect indication (RDI) bit is set in messages that have been received or transmitted. |
Port status TLV |
|
Interface status TLV |
|
Action profile | Name of the action profile occurrence associated with a remote MEP. |
Last event | When an action profile occurs, displays the last event that triggered it. |
Last event cleared | When all the configured and occurred events (under action profile) are cleared, then the action taken gets reverted (such as down interface is made up) and the corresponding time is noted and displayed. |
Action | Action taken and the corresponding time of the action occurrence. |
Sample Output
show oam ethernet connectivity-fault-management mep-database
user@host> show oam ethernet connectivity-fault-management
mep-database maintenance-domain vpls-vlan2000 maintenance-association
vpls-vlan200
Maintenance domain name: vpls-vlan2000, Format: string, Level: 5 Maintenance association name: vpls-vlan200, Format: string Continuity-check status: enabled, Interval: 100ms, Loss-threshold: 3 frames MEP identifier: 200, Direction: up, MAC address: 00:19:e2:b0:74:01 Auto-discovery: enabled, Priority: 0 Interface name: ge-0/0/1.0, Interface status: Active, Link status: Up Defects: Remote MEP not receiving CCM : no Erroneous CCM received : no Cross-connect CCM received : no RDI sent by some MEP : no Statistics: CCMs sent : 1476 CCMs received out of sequence : 0 LBMs sent : 85 Remote MEP count: 1 Identifier MAC address State Interface 100 00:19:e2:b2:81:4b ok vt-0/1/10.1049088
show oam ethernet connectivity-fault-management mep-database local-mep remote-mep
user@host> show oam ethernet connectivity-fault-management
mep-database maintenance-domain vpls-vlan2000 maintenance-association
vpls-vlan200 local-mep 200 remote-mep 100
Maintenance domain name: vpls-vlan2000, Format: string, Level: 5 Maintenance association name: vpls-vlan200, Format: string Continuity-check status: enabled, Interval: 100ms, Loss-threshold: 3 frames MEP identifier: 200, Direction: up, MAC address: 00:19:e2:b0:74:01 Auto-discovery: enabled, Priority: 0 Interface name: ge-0/0/1.0, Interface status: Active, Link status: Up Remote MEP identifier: 100, State: ok MAC address: 00:19:e2:b2:81:4b, Type: Learned Interface: vt-0/1/10.1049088 Last flapped: Never Remote defect indication: false Port status TLV: none Interface status TLV: none
show oam ethernet connectivity-fault-management mep-database remote-mep (Action Profile Event)
user@host> show oam ethernet connectivity-fault-management
mep-database maintenance-domain md5 maintenance-association ma5 remote-mep
200
Maintenance domain name: md5, Format: string, Level: 5 Maintenance association name: ma5, Format: string Continuity-check status: enabled, Interval: 1s, Loss-threshold: 3 frames MEP identifier: 100, Direction: down, MAC address: 00:05:85:73:e8:ad Auto-discovery: enabled, Priority: 0 Interface status TLV: none, Port status TLV: none Interface name: ge-1/0/8.0, Interface status: Active, Link status: Up Remote MEP identifier: 200, State: ok MAC address: 00:05:85:73:96:1f, Type: Configured Interface: ge-1/0/8.0 Last flapped: Never Remote defect indication: false Port status TLV: none Interface status TLV: lower-layer-down Action profile: juniper Last event: Interface-status-tlv lower-layer-down Action: Interface-down, Time: 2009-03-27 14:25:10 PDT (00:00:02 ago)