Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

Navigation

show redundant-power-system status

Syntax

show redundant-power-system status

Release Information

Command introduced in Junos OS Release 12.1 for EX Series switches.

Description

Display the status information for the switch connectors on the Redundant Power System (RPS).

Required Privilege Level

view

List of Sample Output

show redundant-power-system status (Standalone Switch)
show redundant-power-system status (EX3300 Virtual Chassis)

Output Fields

Table 1 lists the output fields for the show redundant-power-system status command. Output fields are listed in the approximate order in which they appear.

Table 1: show redundant-power-system status Output Fields

Field Name

Field Description

Level of Output

RPS

Serial number of the RPS.

All levels

Port

Number of the switch connector.

All levels

Status

Status of the switch connector:

  • ARMED—The switch is ready to get backup power from RPS if power supply fails on the switch.
  • OFF—The switch has zero and is not configured to receive backup power from RPS.
  • BACKED-UP—The switch is receiving power backup from RPS.
  • OVER-SUBSCRIBED—The switch cannot receive backup power from RPS even if you set the .

All levels

Priority

Priority value of the switch connector.

All levels

Power-Requested

Power requested by the switch on the corresponding switch connector.

All levels

Sample Output

show redundant-power-system status (Standalone Switch)

user@switch> show redundant-power-system status
Gathering requested information.
RPS-CG0209121807
Port Status        Power-requested
  0  Armed        3         930W          
  1  Off          1         ---              
  2  Off          1         ---              
  3  Off          1         ---              
  4  Off          1         ---              
  5  Off          1         ---              

show redundant-power-system status (EX3300 Virtual Chassis)

user@switch> show redundant-power-system status
Gathering requested information.
RPS-CG0209121814
Port Status        Power-requested
  0  OFF          1         ---          
  1  OFF          1         ---          
  2  OFF          1         ---          
  3  OFF          1         ---          
  4  OFF          1         ---          
  5  Armed        5         930W         
RPS-CG0209121815
Port Status        Power-requested
  0  OFF          1         ---          
  1  OFF          1         ---          
  2  OFF          1         ---          
  3  OFF          1         ---          
  4  Armed        4         930W         
  5  OFF          1         ---          

Published: 2014-04-23