loss-threshold
Syntax
loss-threshold number;
Hierarchy Level
[edit protocols oam ethernet connectivity-fault-management maintenance-domain domain-name maintenance-association ma-name continuity-check]
Release Information
Statement introduced in Junos OS Release 8.4.
Statement introduced in Junos OS Release 12.1X48 for PTX Series Packet Transport Routers.
Description
Specify the number of continuity check messages lost before marking the remote MEP as down.
Options
number—The number of continuity check messages that can be lost before the remote MEP is considered down.