jnxPingLastTestResultTable

jnxPingLastTestResultTable, whose object identifier is {jnxPingObjects 5}, contains the results of the last completed ping tests. Entries corresponding to a test are created only after completion of the first test. This is useful when you want to ensure that a test has been completed before collecting test results.

The jnxPingLastTestResultEntry objects are listed in Table 1.

Table 1: jnxPingLastTestResultEntry

Object

Object Identifier

Description

jnxPingLastTestResultProbeResponses

jnxPingLastTestResultEntry 1

The number of responses received in the most recently completed test.

jnxPingLastTestResultSentProbes

jnxPingLastTestResultEntry 2

The number of probes sent in the most recently completed test.

jnxPingLastTestResultSumRttUs

jnxPingLastTestResultEntry 3

The sum of the round-trip delays measured for all the probes during the most recently completed test, in microseconds.

jnxPingLastTestResultMinRttUs

jnxPingLastTestResultEntry 4

The minimum of the round-trip delays measured for all the probes during the most recently completed test, in microseconds.

jnxPingLastTestResultMaxRttUs

jnxPingLastTestResultEntry 5

The maximum of the round-trip delays measured for all the probes during the most recently completed test, in microseconds.

jnxPingLastTestResultAvgRttUs

jnxPingLastTestResultEntry 6

The average of the round-trip delays measured for all the probes during the most recently completed test, in microseconds.

jnxPingLastTestResultStdDevRttUs

jnxPingLastTestResultEntry 7

The standard deviation of the round-trip delays measured for all the probes during the most recently completed test, in microseconds.

jnxPingLastTestResultMinEgressUs

jnxPingLastTestResultEntry 8

The minimum of the egress trip delays measured over all probes during the most recently completed test, in microseconds. This applies only if the probe type (pingCtlType) provides one-way delay measurements. For all other probe types, their values are irrelevant and this object returns 0.

jnxPingLastTestResultMaxEgressUs

jnxPingLastTestResultEntry 9

The maximum of the egress trip delays measured over all probes during the most recently completed test, in microseconds. This applies only if the probe type (pingCtlType) provides one-way delay measurements. For all other probe types, their values are irrelevant and this object returns 0.

jnxPingLastTestResultAvgEgressUs

jnxPingLastTestResultEntry 10

The average of the egress trip delays measured over all probes during the most recently completed test, in microseconds. This applies only if the probe type (pingCtlType) provides one-way delay measurements. For all other probe types, their values are irrelevant and this object returns 0.

jnxPingLastTestResultStddevEgressUs

jnxPingLastTestResultEntry 11

The standard deviation of the egress trip delays measured over all probes during the most recently completed test, in microseconds. This applies only if the probe type (pingCtlType) provides one-way delay measurements. For all other probe types, their values are irrelevant and this object returns 0.

jnxPingLastTestResultMinIngressUs

jnxPingLastTestResultEntry 12

The minimum of the ingress trip delays measured over all probes during the most recently completed test, in microseconds. This applies only if the probe type (pingCtlType) provides one-way delay measurements. For all other probe types, their values are irrelevant and this object returns 0.

jnxPingLastTestResultMaxIngressUs

jnxPingLastTestResultEntry 13

The maximum of the ingress trip delays measured over all probes during the most recently completed test, in microseconds. This applies only if the probe type (pingCtlType) provides one-way delay measurements. For all other probe types, their values are irrelevant and this object returns 0.

jnxPingLastTestResultAvgIngressUs

jnxPingLastTestResultEntry 14

The average of the ingress trip delays measured over all probes during the most recently completed test, in microseconds. This applies only if the probe type (pingCtlType) provides one-way delay measurements. For all other probe types, their values are irrelevant and this object returns 0.

jnxPingLastTestResultStddevIngressUs

jnxPingLastTestResultEntry 15

The standard deviation of the ingress trip delays measured over all probes during the most recently completed test, in microseconds. This applies only if the probe type (pingCtlType) provides one-way delay measurements. For all other probe types, their values are irrelevant and this object returns 0.

jnxPingLastTestResult PeakToPeakJitterRttUs

jnxPingLastTestResultEntry 16

The difference between the minimum and maximum delays over the course of the last completed test, in microseconds.

jnxPingLastTestResult PeakToPeakJitterEgressUs

jnxPingLastTestResultEntry 17

The difference between the minimum and maximum egress trip delays over the course of the last completed test, in microseconds. This applies only if the probe type (pingCtlType) provides one-way delay measurements. For all other probe types, their values are irrelevant and this object returns 0.

jnxPingLastTestResult PeakToPeakJitterIngressUs

jnxPingLastTestResultEntry 18

The difference between the minimum and maximum ingress trip delays over the course of the last completed test, in microseconds. This applies only if the probe type (pingCtlType) provides one-way delay measurements. For all other probe types, their values are irrelevant and this object returns 0.

jnxPingLastTestResultTime

jnxPingLastTestResultEntry 19

The time the last test was completed.

Published: 2013-07-16