Supported Platforms
Specifying the Interval Between ANCP Adjacency Messages
When the ANCP agent and a neighbor negotiate to establish an adjacency, each proposes a value for the interval between the adjacency messages that they exchange after it is established. The larger of the values proposed by the agent and the neighbor is selected for the interval between subsequent adjacency messages exchanged by the agent and the neighbor. You can specify the interval value that the ANCP agent proposes for either all neighbors or a specific neighbor.
To configure the proposed interval between ANCP adjacency messages for all neighbors:
- Specify the time in seconds.[edit protocols ancp]user@host# set adjacency-timer 20
To configure the proposed interval between ANCP adjacency messages for a specific neighbor:
- Specify the time in seconds.[edit protocols ancp neighbor 10.2.3.4]user@host# set adjacency-timer 20