Related Documentation
- M, PTX, T Series
- Ethernet DWDM Interface Wavelength Overview
- Additional Information
- Ethernet Interfaces
Configuring the 10-Gigabit or 100-Gigabit Ethernet DWDM Interface Wavelength
To configure the wavelength on a 10-Gigabit Ethernet or 100-Gigabit Ethernet dense wavelength-division multiplexing (DWDM) interface, include the wavelength statement at the [edit interfaces media-type-fpc/pic/port optics-options] hierarchy level:
For interface diagnostics, you can issue the show interfaces diagnostics optics media-type-fpc/pic /port operational mode command.
Table 1 shows configurable wavelengths and the corresponding frequency for each configurable wavelength.
Table 1: Wavelength-to-Frequency Conversion Matrix
Wavelength (nm) | Frequency (THz) | Wavelength (nm) | Frequency (THz) | Wavelength (nm) | Frequency (THz) |
---|---|---|---|---|---|
1528.77 | 196.10 | 1540.56 | 194.60 | 1552.52 | 193.10 |
1529.55 | 196.00 | 1541.35 | 194.50 | 1553.33 | 193.00 |
1530.33 | 195.90 | 1542.14 | 194.40 | 1554.13 | 192.90 |
1531.12 | 195.80 | 1542.94 | 194.30 | 1554.94 | 192.80 |
1531.90 | 195.70 | 1543.73 | 194.20 | 1555.75 | 192.70 |
1532.68 | 195.60 | 1544.53 | 194.10 | 1556.56 | 192.60 |
1533.47 | 195.50 | 1545.32 | 194.00 | 1557.36 | 192.50 |
1534.25 | 195.40 | 1546.12 | 193.90 | 1558.17 | 192.40 |
1535.04 | 195.30 | 1546.92 | 193.80 | 1558.98 | 192.30 |
1535.82 | 195.20 | 1547.72 | 193.70 | 1559.79 | 192.20 |
1536.61 | 195.10 | 1548.52 | 193.60 | 1560.61 | 192.10 |
1537.40 | 195.00 | 1549.32 | 193.50 | 1561.42 | 192.00 |
1538.19 | 194.90 | 1550.12 | 193.40 | 1562.23 | 191.90 |
1538.98 | 194.80 | 1550.92 | 193.30 | 1563.05 | 191.80 |
1539.77 | 194.70 | 1551.72 | 193.20 | 1563.86 | 191.70 |
Related Documentation
- M, PTX, T Series
- Ethernet DWDM Interface Wavelength Overview
- Additional Information
- Ethernet Interfaces
Published: 2013-08-01
Related Documentation
- M, PTX, T Series
- Ethernet DWDM Interface Wavelength Overview
- Additional Information
- Ethernet Interfaces